50. Local Key Operation (Command: t o)
Configures the local key operation settings of the product.
Transmission
[t][o][ ][Set ID][ ][Data][Cr]
Data 00: locks off all of the keys
01: locks on all of the keys except the Power
key
02: locks on all of the keys
Acknowledgement
[o][ ][Set ID][ ][OK/NG][Data][x]
51. Status (Command: s v)
Checks the current signal status of the product.
Transmission
[s][v][ ][Set ID][ ][Data][ ][FF][Cr]
Data 02: checks whether there is a signal or not
10: RGB sensing OK/NG (Check Screen)
Acknowledgement
[v][ ][Set ID][ ][OK/NG][Data][Data1][x]
Data: 02 (when a signal is found)
Data1 00: no signal
01: there is a signal
Data: 10 (Check Screen)
Data1 00: Check Screen result NG
07: Check Screen result OK
* Treated as NG if Check Screen is set to Off
52. Check Screen (Command: t z)
Sets Check Screen.
Transmission
[t][z][ ][Set ID][ ][Data][Cr]
Data 00: Off
01: On
Acknowledgement
[z][ ][Set ID][ ][OK/NG][Data][x]
53. Speaker (Command: d v)
Sets the speaker function.
Transmission
[d][v][ ][Set ID][ ][Data][Cr]
Data 00: Off
01: On
Acknowledgement
[v][ ][Set ID][ ][OK/NG][Data][x]
54. Daylight Saving Time (Command: s d)
To set theDaylight Saving Time function.
Transmission
[s][d][ ][Set ID][ ][Data1][ ][Data2][ ][Data3][ ][Data4]
[ ][Data5][Cr]
Data 00: Off (Data2~5: FFH)
01: Start Time
02: End Time
Data2 01~0C: January to December
Data3 01~06: 1 ~ 6th week
* The maximum number of [Data3] differs depending
on Date.
Data4 00~06 ( Sun. ~ Sat. )
Data5 00~17: 00 ~ 23 hours
* To read the Start Time/End Time, enter FFH for
[Data2]~[Data5].
(ex1: sd 01 01 ff ff ff ff - To check the Start Time
ex2: sd 01 02 ff ff ff ff - To check the End Time)
* This function is supported only when 1 (Year/Month/
Day) and 2 (Hour/Minute/Second) are set.
Acknowledgement
[d][ ][Set ID][ ][OK/NG][Data1][Data2][Data3][Data4]
[Data5][x]