LG Electronics M2901S Computer Monitor User Manual


 
Controlling the Multiple Product
RS-232C
A7A7
Transmission / Receiving Protocol
16. Time(Command : f a)
► Set the current time.
Transmission Acknowledgement
17. On Timer On/Off(Command : f b)
► Set days for On Timer.
Transmission Acknowledgement
[Data1]
0 (Write), FFH(Read)
[Data2]
00 H to FFH
bit0 : Monday On Timer On(1), Off(0)
bit1 : Tuesday On Timer On(1), Off(0)
bit2 : Wednesday On Timer On(1), Off(0)
bit3 : Thursday On Timer On(1), Off(0)
bit4 : Friday On Timer On(1), Off(0)
bit5 : Saturday On Timer On(1), Off(0)
bit6 :Sunday On Timer On(1), Off(0)
bit7 : Everyday On Timer On(1), Off(0)
[Data1]
0 : Monday
1 : Tuesday
2 : Wednesday
3 : Thursday
4 : Friday
5 : Saturday
6 : Sunday
[Data2]
00 H to 17 H : 00 to 23 Hours
[Data3]
00 H to 3 BH : 00 to 59 Minutes
* When reading data, FFH is inputted for
[Data1], [Data2] and [Data3].
In other cases, all are treated as NG.
[f][a][][Set ID][][Data1][Data2][Data3][Cr]
[f][b][][Set ID][][Data1][Data2][Cr]
[a][][Set ID][][OK/NG][Data1][Data2][Data3][x]
[b][][Set ID][][OK/NG][Data1][Data2][x]