Liebert PSA650MT-120 Power Supply User Manual


 
PowerSure
PSA
Quick-Start Guide for 350-1000VA; 120V
WHATS IN THE BOX
Quick-Start guide
PowerSure family user manual on CD (also at www.liebert.com)
Warranty card
MultiLink
software CD
MultiLink serial cable (M3LS9P9S), 10 ft. (3m)
RJ-11 cord, 7 ft. (2.1m)
USB cable, 6 ft. (1.8m)
For more details, refer to the PowerSure user manual on CD.
Para una información más detallada, consulte el manual del usuario
de la familia PowerSure en el CD.
PowerSure PSA
* Power ON/OFF/
Alarm Silence
* Fault Indicator
(Red/Green)
* Utility Indicator
(Green)
Battery Indicator *
(Green/Amber)
DIP switches **
*** USB port
*** DB-9 port
Site Wiring Fault *
Indicator (Red)
** Orange output recep-
tacles (battery backup
and surge protection)
(4 receptacles on 350,
500 and 650VA models)
** Black output
receptacles (surge
protection only)
6-ft. (1.8m)
power cord
Battery cover plate
(on bottom for
650&1000VA models)
(on rear of 350&500VA
models)
Data Line ***
Protection
Connectors
For details, see :
* Controls and Indicators
** Installation
*** Communications
INSTALLATION
Read all safety, installation and operating instructions in the PowerSure family user manual on the included CD or
at www.liebert.com before operating the UPS. Adhere to all warnings on the unit and in the manual.
1. Install the UPS indoors in a controlled environment, where it cannot be accidentally turned off. Place it in an area
of unrestricted airflow around the unit, away from water, flammable liquids, gases, corrosives and conductive
contaminants. Maintain a minimum clearance of 4 inches (100mm) on each side of the UPS. Maintain an ambi-
ent temperature range of 32°F to 104°F (0°C to 40°C).
2. Plug the PSA’s power cord into an AC outlet. Check the Site Wiring Fault Indicator on the rear; if it is illuminated,
refer to the Troubleshooting section.
3. Plug any computers and monitors into the orange receptacles for battery backup and surge protection; other
office machines that do not exceed the capacity of the UPS may be plugged into either of the two (2) black
receptacles, which provide surge protection only.
4. Connect Phone/Fax/DSL/Internet/Modem devices to data line connectors.
5. Press and release the ON/OFF/Alarm Silence button to turn on the UPS. The UPS will beep and the Utility Indi-
cator will illuminate (green).
6. Turn on connected equipment.
Plug this type of equipment into
black receptacles ONLY
Plug computers, monitors & network hubs
into orange receptacles
Inkjet printers
Scanners
Fax machines
COMMUNICATIONS
The PowerSure PSA will communicate with your computer in either of two ways: over its DB-9 port through Lie-
bert’s MultiLink
software or by USB through Microsoft
®
Windows
®
operating system features.
MultiLink supplies useful monitoring data, such as input voltage and battery level, and will perform an orderly shut-
down of the computer system. Microsoft Windows XP and 2000 operating system utilities supply UPS status infor-
mation and will perform an orderly computer shutdown. Check your computer’s OS features to determine whether
it has power management capability.
For MultiLink Serial Communications
Connect the provided MultiLink serial cable to the DB-9 ports on the rear of the UPS and on the rear of your
computer.
Install the MultiLink software—the software, installation instructions and the user manual are on the CD included
in the PowerSure PSA package.
For USB Communications (with operating system power management)
Connect the USB cable provided with the UPS to the USB ports on the PSA and your computer. The PSA will
work automatically with the built-in power management software on Windows XP and 2000 or later.
All USB models are compatible with Microsoft Windows 2000, Windows XP and Macintosh
®
OS 10.2 or later.
CONTROLS AND INDICATORS
This button controls output power to the connected
load and has three functions:
Turns the PowerSure PSA ON
Turns the PowerSure PSA OFF
Silences PowerSure PSA alarms
TURN THE UPS ON: Press and release the main ON/OFF
button to start the UPS. An audible alarm will sound briefly.
TURN THE UPS OFF: When the PSA is ON, hold the main
ON/OFF button down for more than 2 seconds to shut it down.
An audible alarm will sound briefly.
SILENCE AN ALARM: When a UPS alarm is active, press and
release the main ON/OFF button to silence the audible alarm
(Exceptions: low battery, overload and overtemperature). DO
NOT hold the button down for more than 2 seconds or the PSA
will shut down.
CHECK THE PSA’S CONDITION: Three status indicators on
the front of the UPS illuminate to specify the status of the UPS
(see Troubleshooting section for details).
SITE WIRING FAULT INDICATOR (RED)
The Site Wiring Fault Indi-
cator on the rear panel, as
shown, illuminates red
when the UPS detects a
line-neutral reversal or a
poor neutral-ground. (See
Troubleshooting Chart if
indicator is illuminated.)
TRANSFER VOLTAGE SELECTORS (DIP SWITCHES)
The two-position DIP switch control on the rear panel, shown
above, allows the operator to select the utility transfer voltage
at which the UPS will switch to battery power. The factory
default settings are 100VAC - 135VAC. DIP switch positions for
each voltage setting are:
DIP switch settings
Left Right Nominal Utility Setting
Up Up 120VAC 85 - 145VAC (default)
Up Down 110VAC 78 - 138VAC
Down Up 127VAC 90 - 150VAC
Down Down 120VAC 85 - 145VAC
!
CAUTION
Never change the voltage settings while the UPS
is ON and powering connected loads. Change
DIP switches only when the UPS is OFF.
!
CAUTION
To ensure protection of the connected
equipment, the DIP switch settings should match
the nominal utility input voltage. DIP switch
settings not matching the nominal utility could
potentially damage connected equipment.
Fault Indicator
Green: Overload/
Overtemperature
Red: UPS fault
Utility Indicator
Green: Normal operation
Amber: Buck/Boost
mode
Battery Indicator
Green: On battery
Amber: Battery
warning
DIP Switches
Site Wiring
Fault
Indicator
(Red)
Rear of UPS
SPECIFICATIONS
Model Number
PSA350MT-120 PSA500MT-120 PSA650MT-120 PSA1000MT-120
Power Rating VA/W
350VA/210W 500VA/300W 650VA/390W 1000VA/600W
DIMENSIONS: in. (mm)
Unit
WxDxH
4.6x7.7x8.7
(116x196x222)
4.6x7.7x8.7
(116x196x222)
4.6x14.1x8.7
(116x358x222)
4.6x14.1x8.7
(116x358x222)
Shipping
WxDxH
7.7x12.2x11.5
(196x310x293)
7.7x12.2x11.5
(196x310x293)
9.5x19.7x12.4
(242x500x316)
9.5x19.7x12.4
(242x500x316)
WEIGHT: lbs (kg)
Unit 16.8 (7.6) 17.2 (7.8) 20.7 (9.4) 29.7 (13.5)
Shipping 18.1 (8.2) 18.5 (8.4) 22.9 (10.4) 31.9 (14.5)
INPUT AC PARAMETERS
Surge Protection 570J
Voltage Range Without
Battery Operation
78VAC - 150VAC, DIP switch selectable
(see “DIP switch settings” on page1)
Frequency Range 46.5 - 63.5 Hz (±0.1 Hz)
Input Power Cord 6 ft. (1.8m) attached, w/ NEMA 5-15 P
OUTPUT AC PARAMETERS
Output Receptacles
(4) NEMA 5-15R (orange)
Battery backup + surge protection;
(2) NEMA 5-15R (black)
Surge protection
(6) NEMA 5-15R
(orange) Battery
backup + surge
protection;
(2) NEMA 5-15R
(black) Surge
protection
Voltage (Normal mode) Nominal (110, 120, 127VAC) ±10%
Voltage (Battery mode) 120VAC ±8%
Output Current 2.9 A 4.2 A 5.4 A 8.3 A
Waveform (Battery mode) Stepped Sinewave
Frequency 50 Hz or 60 Hz; auto sensing
Overload Warning
(Normal & Battery modes)
>100%
Overload Shutdown >110%
BATTERY PARAMETERS
Type Valve-regulated, nonspillable, lead acid
QuantityxVoltagexRating (1)x12Vx7Ah (1)x12Vx9Ah (1)x12Vx9Ah (2)x12Vx7.5Ah
Transfer Time 4 - 6 ms typical
Backup Time: At 77°F (25°C), resistive loading, with fully charged batteries:
Full Load 8 minutes 8 minutes 5 minutes 5 minutes
Half Load 26 minutes 24 minutes 16 minutes 18 minutes
Recharge Time
6 hours to 90% of rated capacity,
after full discharge into resistive load
ENVIRONMENTAL (ALL MODELS)
Operating
Temperature
+32°F to +104°F
(0°C to +40°C)
Storage
Temperature
+5°F to +104°F
(-15°C to +40°C)
Relative
Humidity
0% to 95%, non-
condensing
Operating
Elevation
Up to 10,000 ft.
(3000m) at 86°F (30°C)
without derating
Audible Noise < 40 dBA, at 1 meter
AGENCY
Safety UL 1778, c-UL Listed
Surge
ANSI C62.41, Category
A, Level 3
(IEEE 587, Category A);
EN61000-4-5, Level 3,
Criteria A
ESD
EN61000-4-2, Level 3,
Criteria A
Susceptibility
EN61000-4-3, Level 3,
Criteria A
Electrical Fast
Transient/Burst
EN61000-4-4, Level 4,
Criteria A
Emissions
FCC Part 15, Subpart B,
Class B
Conducted
Immunity
EN61000-4-6, Level 3,
Criteria A
Harmonics EN61000-3-2
Flicker EN61000-3-3
Transportation ISTA Procedure 1A