Linksys SFE2000P Switch User Manual


 
256
Chapter 16:
SFE2000/SFE2000P Gigabit Ethernet Switch Reference Guide
Chapter
16
Sampling Interval — Indicates in seconds the time that samplings are taken from the ports. The
field range is 1-3600. The default is 1800 seconds (equal to 30 minutes).
Sampling Requested — Displays the number of samples to be saved. The field range is 1-65535.
The default value is 50.
Current Number of Samples — Displays the current number of samples taken.
Owner — Displays the RMON station or user that requested the RMON information. The field
range is 0-20 characters.
3. Click the Add button. The Add RMON History Page opens:
Add RMON History Page
The Add RMON History Page contains the following fields:
New History Entry — Number automatically assigned to the table entry number.
Source Interface — Displays the interface from which the history samples were taken. The possible
field values are:
Port — Specifies the port from which the RMON information was taken.
LAG — Specifies the port from which the RMON information was taken.
Owner — Displays the RMON station or user that requested the RMON information. The field
range is 0-20 characters.
Max No. of Samples to Keep — Indicates the number of samples to save.
Sampling Interval — Indicates in seconds the time that samplings are taken from the ports. The
field range is 1-3600. The default is 1800 seconds (equal to 30 minutes).
4. Define the relevant fields.
5. Click Apply. The entry is added to the RMON History Control Page, and the device is updated.