MicroNet Technology SP1659P Switch User Manual


 
set state
Syntax: set state <port-range> <state>
Description: To set the PoE state on ports.
Argument:
<port-range>which port(s) you want to set, syntax 1,5-7, available from 1 to 24
<state>: enable or disable PoE function. 0: Disable, 1: Enable
Possible value:
<port-range>1 to 24
<state>: 0 or 1
Example:
SP1659P(poe)# set state 11 0
SP1659P(poe)#
show
Syntax: Show
Description: To display the PoE status.
Argument: None
Possible value: None
Example:
SP1659P(poe)# show
Vmain : 48.1 V
Imain : 0.06 A
Pconsume : 3.1 W
Power Limit : 185 W
Temperature : 40 'C / 104 'F
Port No | 1 2 3 4 5 6 7 8 9 10 11 12
------------------------------ | - - - - - - - - - -- -- --
Port On | X V X X X X X X X X X X
AC Disconnect Port Off | X X X X X X X X X X X X
DC Disconnect Port Off | X X X X X X X X X X X X
Overload Port Off | X X X X X X X X X X X X
Short Circuit Port Off | X X X X X X X X X X X X
Over Temp. Protection | X X X X X X X X X X X X
Power Management Port Off | X X X X X X X X X X X X
Port No | 13 14 15 16 17 18 19 20 21 22 23 24
------------------------- | -- -- -- -- -- -- -- -- -- -- -- --
Port On | X X X X X X X X X X X X
AC Disconnect Port Off | X X X X X X X X X X X X
DC Disconnect Port Off | X X X X X X X X X X X X
Overload Port Off | X X X X X X X X X X X X
Short Circuit Port Off | X X X X X X X X X X X X
Over Temp. Protection | X X X X X X X X X X X X
Power Management Port Off | X X X X X X X X X X X X
Port Status State Priority Power(W) Current(mA) Class
-------------------------------------------------------------------------
1 Normal Enable Normal 0.0 0 0
2 Active Enable Normal 3.0 66 2
3 Normal Enable Normal 0.0 0 0
4 Normal Enable Normal 0.0 0 0
5 Normal Enable Normal 0.0 0 0
6 Normal Enable Normal 0.0 0 0
7 Normal Enable Normal 0.0 0 0
8 Normal Enable Normal 0.0 0 0
9 Normal Enable Normal 0.0 0 0
96