Mitsubishi Electronics GT15-RS2/4-U Laser Pointer User Manual


 
User's Manual
GT15-RS2-9P
GT15-RS4-9S
GT15-RS4-TE
Thank you for purchasing the GOT1000 Series.
GT15 Serial communication unit
Prior to use, please read both this manual and detailed
manual thoroughly to fully understand the product.
MODEL GT15-RS2/4-U
MODEL
CODE
1D7M40
IB(NA)-0800325-A(0507)MEE
zSAFETY PRECAUTIONSz
(Always read these precautions before using this equipment.)
Before using this product, please read this manual and the relevant
manuals introduced in this manual carefully and pay full attention to
safety to handle the product correctly.
The precautions given in this manual are concerned with this prod-
uct.
In this manual, the safety precautions are ranked as "DANGER" and
"CAUTION".
Note that the CAUTION level may lead to a serious accident
according to the circumstances.
Always follow the precautions of both levels because they are impor-
tant to personal safety.
Please save this manual to make it accessible when required and
always forward it to the end user.
Indicates that incorrect handling may cause
hazardous conditions, resulting in death or
severe injury.
Indicates that incorrect handling may cause
hazardous conditions, resulting in medium or
slight personal injury
or physical damage.
DANGER
CAUTION
[DESIGN PRECAUTIONS]
[INSTALLATION PRECAUTIONS]
[WIRING PRECAUTIONS]
[STARTUP AND MAINTENANCE PRECAUTIONS]
z Do not bunch the control wires or communication cables with
the main circuit or power wires, or lay them close to each other.
As a guide, separate the lines by a distance of at least 100 mm
(3.94 inch) otherwise malfunctions may occur due to noise.
z Be sure to shut off all phases of the external power supply used
by the system before mounting or removing this unit to/from the
GOT.
Not doing so can cause a unit failure or malfunction.
z Before connecting the Bus connection cable to this unit, always
shut off GOT power and PLC CPU power externally in all
phases.Not doing so can cause a malfunction.
z Use this unit in the environment given in the general
specifications of the GT15 User's Manual.Not doing so can
cause an electric shock, fire, malfunction or product damage or
deterioration.
z When installing this unit to the GOT, fit it to the connection
interface of the GOT and tighten the mounting screws in the
specified torque range.
Undertightening can cause a drop, failure or malfunction.
Overtightening can cause a drop, failure or malfunction due to
screw or unit damage.
z Be sure to shut off all phases of the external power supply used
by the system before wiring.
Failure to do so may result in an electric shock, product damage
or malfunctions.
z Use crimp-contact, pressure-displacement or soldering to wire
the connectors for external connections properly using the
manufacturer-specified tools.
If the connection is incomplete, it may cause the module to short
circuit, catch fire, or malfunction.
z Connect the connectors to the unit securely.
z Always secure the cables connected to the unit, e.g. run them in
conduits or clamp them.
Not doing so can cause unit or cable damage due to dangling,
moved or accidentally pulled cables or can cause a malfunction
due to a cable contact fault.
z Before starting cleaning, always shut off GOT power externally
in all phases. Not doing so can cause a unit failure or
malfunction.
DANGER
DANGER
CAUTION
DANGER
CAUTION
DANGER
[DISPOSAL PRECAUTIONS]
[TRANSPORTATION PRECAUTIONS]
Manuals
The following shows manuals relevant to this product.
For relevant manuals, refer to the PDF manual stored within the
drawing software used.
© 2005 MITSUBISHI ELECTRIC CORPORATION
Product Componets
The serial commnunication units consists of the following items.
* For handling of the ferrite core, refer to "For users intending to
connect the GOT directly to a PLC using the RS-422 cable
(GT01-C30R4-25P)" provided with the product.
z Do not disassemble or modify any unit.
This will cause failure, malfunction, injuries, or fire.
z Do not touch the conductive areas and electronic parts of this
unit directly.
Doing so can cause a unit malfunction or failure.
z Exercise care to avoid foreign matter such as chips and wire
offcuts entering the unit.
Not doing so can cause a fire, failure or malfunction.
z Do not hold the cable part when unplugging any cable
connected to the unit. Doing so can cause unit or cable damage
or a malfunction due to a cable contact fault.
z Always make sure to touch the grounded metal to discharge the
electricity charged in the body, etc., before touching the unit.
Failure to do so may cause a failure or malfunctions of the unit.
z Dispose of this product as industrial waste.
z Make sure to transport the GOT main unit and/or relevant unit(s)
in the manner they will not be exposed to the impact exceeding
the impact resistance described in the general specifications of
the GT15 User's Manual, as they are precision devices.
Failure to do so may cause the unit to fail.
Check if the unit operates correctly after transportation.
Detailed Manual
Manual name
Manual Number
(Type code)
GT15 User's Manual
(Option)
SH-080528ENG
(1D7M23)
GOT1000 Series Connection Manual
(Option)
SH-080532ENG
(1D7M26)
Relevant Manuals
Model name Product mane Quantity
GT15-RS2-9P
GT15-RS2-9P 1
Mounting screw set (2 screws, 2 labels) 1
GT15-RS4-9S
GT15-RS4-9S 1
Mounting screw set (2 screws, 2 labels) 1
Ferrite Core* 1
GT15-RS4-TE
GT15-RS4-TE 1
Mounting screw set (2 screws, 2 labels) 1
Terminal block socket 1
CAUTION
CAUTION
CAUTION
1. Overview
This User's Manual describes the GT15 Serial communication
unit. (hereafter abbreviated to the serial communication unit)
The following shows the kinds of the serial communication unit.
For attachable GOTs, refer to the GT15 User's Manual.
The serial communication unit is used when performing the
serial communication between GOT and a FA device.
Select a serial communication unit according to the connection
type.
For the details of connection types, refer to the GOT1000
Series Connection Manual.
2. Specifications
2.1 Performance Specifications
The performance specifications of the serial communication
unit are indicated below.
Refer to the used GT15 User's Manual for the general
specifications of the serial communication unit.
* The maximum transmission distance differs depending on the
controller connected.
For details, refer to the GOT1000 Series Connection Manual.
2.2 Specifications of terminal block socket
Model name Description
GT15-RS2-9P
RS-232 serial communication unitInterface: D-Sub
9-pin (Male)
GT15-RS4-9S
RS-422/485 serial communication unitInterface: D-
Sub 9-pin (Female)
GT15-RS4-TE
RS-422/485 serial communication unitInterface:
Terminal block
Item
Specification
GT15-RS2-9P GT15-RS4-9S GT15-RS4-TE
Transmission
method
RS-232
compliant
RS-422/485
compliant
RS-22/485
compliant
Interface
D-sub 9-pin
(Male)
D-sub 9-pin
(Female)
Terminal block
Transmission speed 115200/57600/38400/19200/9600/4800bps
Synchronous type Non-Synchronous type (Asynchronous type)
Error detection
method
Parity check, sum check
Maximum
transmission
distance
15m 1200m* 1200*
Imternal current
consumption(5V)
0.20A
Weight 0.09kg
Item Specifications
Screw tightening torque 0.20 to 0.25 [N•m
2
]
Recommended driver
DIN 5265: ISO 2380/2 compliant product
DIN 5264: Product with the tip chrome-plated
based on the ISO 2380/1 standard
Applicable wire size 0.08 to 1.5 [mm
2
]
3. Name of the Parts and External Dimen-
sions
(1) GT15-RS2-9P / PS4-9S
(2) GT15-RS4-TE
Dimensions of X when mounted to the GOT.
Unit: mm (inch)
(3) Back view (GT15-RS4-9S / TE)
8.4” 23 (0.91)
10.4”, 12.1”, 15” 21 (0.83)
1)
7)
3)
4)
X
98 (3.89)7
(0.28)
112 (5)
2.5
(0.10)
30.5 (1.2)
21.5
(0.85)
3
(0.12)
GOT main
unit
63 (2.48)
0.5
(0.02)
2)
31.5
(1.24)
9
(0.35)
1)
7)
3)
4)
5)
X
GOT main
unit
63 (2.48) 3
(0.12)
98 (3.89)
12
(0.47)
2.5
(0.10)
30.5 (1.2)
21.5
(0.85)
117 (4.61)
0.5
(0.02)
2
)
29.5
(1.16)
11.5
(0.45)
6)
(Expanded figure of part 6))
ON KSD22S
12
100 OHM
ON
SW1
4. Installation Procedure
4.1 Serial communication unit installation
The following figures show an example of the GT15-RS2-9P/
RS4-9S installation.The installation of the GT15-RS4-TE
follows the same procedure.
(1) Power off the GOT.
(2) Remove the one extension unit covers of the GOT.
(3) Fit the Ethernet communication unit along the groove
of the GOT case.
(4) Fasten the Ethernet communication unit by tightening
its mounting screws (2 places) with tightening torque
0.36 to 0.48 N•m.
No. Name Description
1) Mounting screw
Mounting screws fixed with the front
communication unit or GOT.
2)
Interface
connector
Connector connected to the front communication
unit or GOT.
3)
Extension
connector
Connector with which the back communication
unit is fixed.
4)
Serial
communication
connector
Connector for connecting a serial communication
cable (For GT15-RS4-TE, the terminal block
socket is connected.)
5)
Terminal block
socket
Connects a serial communication cable to the
serial communication connector.
6)
DIP switch
(For GT15-RS4-
9S/TE only)
Switch to set terminating resistor.When using the
built-in terminating resistor (100
), turn both No.
1 and No. 2 switches on.When using the external
terminating resistor, turn both No. 1 and No. 2
switches off.
7) Rating plate -
(5) When installing a communication unit on the outer
layer, remove the connector cover and peel the seal.
When not mounting any communication unit on the
outer layer, stick accessory labels on the top of
mounting screws (2 places) to cover the top of them
in order to avoid receiving electrostatic.
Keep the connector cover fixed.
Keep the seal stuck as it is.
4.2 Terminal block socket installation
(For GT15-RS4-TE only)
(1) Insert the terminal block socket in the serial
communication unit.
(2) Fasten the terminal block by tightening the terminal
block fixing screws (2 places) with the tightening
torque of 0.20 to 0.25 Nm.
(Expanded figure of part A)
Point
If you remove the serial communication unit, detach it from
specified direction (shown PULL) so as not to break a connector.
Point
When attaching or removing a communication cable to/from the
terminal block socket, detach the terminal block socket from the
connector.
(When communication units are installed in multiple layers, the units
do not have to be removed from the GOT main unit.)
Seal
A
ccessory
labels
Connector
cover
A
A terminal block fixing screw
Warranty
Mitsubishi will not be held liable for damage caused by factors found
not to be the cause of Mitsubishi; machine damage or lost profits
caused by faults in the Mitsubishi products; damage, secondary
damage, accident compensation caused by special factors
unpredictable by Mitsubishi; damages to products other than
Mitsubishi products; and to other duties.
For safe use
This product has been manufactured as a general-purpose part for
general industries, and has not been designed or manufactured to
be incorporated in a device or system used in purposes related to
human life.
Before using the product for special purposes such as nuclear
power, electric power, aerospace, medicine or passenger
movement vehicles, consult with Mitsubishi.
This product has been manufactured under strict quality control.
However, when installing the product where major accidents or
losses could occur if the product fails, install appropriate backup or
failsafe functions in the system.
C
ountry/Region Sales office/Tel
U.S.A Mitsubishi Electric Automation Inc.
500 Corporate Woods Parkway Vernon Hills, IL 60061
Tel : +1-847-478-2100
Brazil MELCO-TEC Rep. Com.e Assessoria Tecnica Ltda.
Rua Correia Dias, 184, Edificio Paraiso Trade Center-8 andar
Paraiso, Sao Paulo, SP Brazil
Tel : +55-11-5908-8331
G
ermany Mitsubishi Electric Europe B.V. German Branch
Gothaer Strasse 8 D-40880 Ratingen, GERMANY
Tel : +49-2102-486-0
U.K Mitsubishi Electric Europe B.V. UK Branch
Travellers Lane, Hatfield, Herts., AL10 8XB,UK
Tel : +44-1707-276100
Italy Mitsubishi Electric Europe B.V. Italian Branch
Centro Dir. Colleoni, Pal. Perseo-Ingr.2
Via Paracelso 12, 20041 Agrate B., Milano, Italy
Tel : +39-039-6053344
S
pain Mitsubishi Electric Europe B.V. Spanish Branch
Carretera de Rubi 76-80
08190 - Sant Cugat del Valles, Barcelona, Spain
Tel : +34-93-565-3131
France Mitsubishi Electric Europe B.V. French Branch
25 Boulevard des Bouvets, F-92741 Nanterre Cedex, France
TEL: +33-1-5568-5568
S
outh Africa Circuit Breaker Industries LTD.
Tripswitch Drive, Elandsfontein Gauteng, South Africa
Tel : +27-11-928-2000
Hong Kong Ryoden Automation Ltd.
10th Floor, Manulife Tower, 169 Electric
Road, North Point, HongKong
Tel : +852-2887-8870
C
hina Ryoden Automation Shanghai Ltd.
3F Block5 Building Automation
Instrumentation Plaza 103 Cao Bao Rd. Shanghai 200233 China
Tel : +86-21-6120-0808
T
aiwan Setsuyo Enterprise Co., Ltd.
6F., No.105 Wu-Kung 3rd.RD, Wu-Ku Hsiang,
Taipei Hsine, Taiwan
Tel : +886-2-2299-2499
Korea HAN NEUNG TECHNO CO.,LTD.
1F Dong Seo Game Channel Bldg.,660-11, Deungchon-dong
Kangsec-ku, Seoul, Korea
Tel : +82-2-3660-9552
S
ingapore Mitsubishi Electric Asia Pte, Ltd.
307 Alexandra Road #05-01/02,
Mitsubishi Electric Building Singapore 159943
Tel : +65-6473-2308
T
hailand F. A. Tech Co.,Ltd.
898/28,29,30 S.V.City Building,Office Tower 2, Floor 17-18 Rama 3
Road, Bangkpongpang, Yannawa, Bangkok 10120
Tel : +66-2-682-6522
Indonesia P.T. Autoteknindo SUMBER MAKMUR
Jl. Muara Karang Selatan Block a Utara No.1 Kav. No.11 Kawasan
Industri/Pergudangan Jakarta - Utara 14440
Tel : +62-21-663-0833
India Messung Systems Put,Ltd.
Electronic Sadan NO:111 Unit No15, M.I.D.C BHOSARI,
PUNE-411026, India
Tel : +91-20-712-2807
A
ustralia Mitsubishi Electric Australia Pty. Ltd.
348 Victoria Road, PostalBag, No 2,
Rydalmere, N.S.W 2116, Australia
Tel : +61-2-9684-7777
HEAD OFFICE : 1-8-12, OFFICE TOWER Z 14F HARUMI CHUO-KU 104-6212,JAPAN
NAGOYA WORKS : 1-14, YADA-MINAMI 5-CHOME, HIGASHI-KU, NAGOYA, JAPAN
When exported from Japan, this manual does not require application to the Ministry
of Economy, Trade and Industry for service transaction permission.
Specifications subject to change without notice.
Printed in Japan on recycled paper.