MRV Communications TS5000/4U1/V*) Mouse User Manual


 
MRV Communications, Inc. – Installation Manual
54
Product Specifications
TS5000/G
Part Number
TS5000G/XXX/V** or TS5000G/XXX/F**
Model
TS5000/G or TS5000/G-F
Standard P.N
TS5000G/M8C/V1S
Application /
Data Protocol
Escon, 622Mbps, Fiber channel, Giga-Ethernet and
others between 100 and 1500Mbps
Rate 100-1500 Mbps
Not attenuated (3 TXs) Attenuated (2 TXs)
Range @ 3dB/km 3500 m 3100 m
@ 5dB/km 2750 m 2500 m
@ 10dB/km 1850 m 1650 m
@ 17dB/km 1300 m 1200 m
@ 30dB/km 870 m 820 m
Minimum Range 700 m 500 m
Bit Error Rate Less than 1E-12 (unfaded)
Performance
MTBF 10 years
Light source 3 x Lasers
Wavelength 830-860 nm
Total Output power 70 - 140 mW
Transmitter
Beam divergence 2 mrad
Detector APD
Field of view 5 mrad
Receiver
Sensitivity -33 dBm
Type
Fiber Optic Transceiver - Multimode (Single mode available upon
request)
Connectors SC (other connectors available)
Wavelength 850 nm (other wavelength available)
Output power -4 to -9.5 dBm
RX operating range 0 to 17 dBm
Interface
Built-in Fusion Optional
Power Supply
Factory set: 100-240 VAC @ 50/60 Hz or 35-60 VDC (V3 and F3 versions)
(30 W)
Operating Temp.
-30 °C to +60 °C
Storage Temp.
-50 °C to +70 °C
Humidity 95% non-condensing
Housing Weatherproof – IP 66
Environmental
Information
Eye safety Class 1M
Dimensions [mm] 790 X 390 X 556 (AD-5000: 250x353x432)
Unit 14 kg Weight
Accessories 21.5Kg
Mechanical
Design
Modularity
Modular Power supply, Modular Interface,
Redundant Power supply - optional
Indicators Airlink: Flag, Sync. Fiber Optic: Flag, Sync.
Alignment, Loopback, Fusion: Enabled/Active, Heating status (if
exists), Control mode: Hardware mode or software mode.
Power supply status, Heating active, Receive Signal Strength
(Digital Display), Lasers status (3 LEDs), SNMP TX and RX
Selectors
Alignment, Loopback (local), Remote Loopback, Fusion
activation, Signal attenuation for Short distance, Heating activation
(if exists), IP address setup, Control mode.
Dry Contact
Two pairs of Pins of the management RJ45 connector can be
used for dry contact purposes, for Airlink flag and F/O flag alarms
Diagnostics
Indicators
and
Selectors
Management SNMP Protocol – Built-in
APPENDIX A