MRV Communications TS5000/ETH/V* Mouse User Manual


 
MRV Communications, Inc. – Installation Manual
11
Back Panel Description
Table 3: TS5000/155 Back Panel Controls, Interfaces, and Indicators
Note:
Pins (4, 5) and (7, 8) of the management RJ45 connector can be used for dry contact
purposes, for Airlink flag and F/O flag alarms respectively
.
Alignment Telescope
For fine alignment.
Power Supply
Pluggable AC power supply (100 to 240 Vac) or
DC power supply (35 to 60 Vdc)
Power
Slot for Power Supply
This slot can house an additional power supply to
be fed from backup voltage source. This can be
independent of primary voltage source for
maximum redundancy.
Power Power source Terminal Block (Main or UPS).
AC power supply (100 to 240 Vac) or DC power
supply (35 to 60 Vdc)
Fiber optic
Fiber Optic interface for connection to the
peripheral equipment. The standard interface is MM
1310nm SC connector; other interfaces are available
upon request (refer to price list or data sheet).
In model TS5000/155-F with the fusion option,
there are two fiber optic interface ports for
connection to the Fusion system; one primary and
the other redundant.
Remote Monitor Connection to an optional Remote Status Monitor
(RSM) or to RSM-DC (for Dry Contact connection)
(not included in the standard transceiver kit)
Connectors
Management
Connection to 10Base-T SNMP management
interface. Pins 1,2: TX and 3,6 RX.
Pins (4,5) and (7,8) of this connector can be used for
dry contact purposes, for Airlink flag and F/O flag
alarms respectively