Murphy 75160 Series Network Card User Manual


 
IR-03063B page 1 of 2
Description
The 75160 series:
This Swichgage panel is specifically config-
ured for irrigation engines and includes loss of
pump discharge pressure Swichgage instru-
ment. The panel is enclosed on top, bottom,
and both ends. Mounting flanges extend on
top and bottom. The back of the panel is open.
Access holes are in the bottom.
75160: includes low oil pressure, high coolant
temperature, low pump pressure Swichgage
instruments, Magnetic Switch, and emergency
stop button.
75160D: includes SV-series solenoid diesel
fuel valve (specify voltage).
For diesel engines without shut-down solenoid
in the injection pump, add a Murphy SV
Series solenoid fuel shut-off valve or RP2300
Series rack pull solenoid.
Panel Kits Include:
Low Lube Oil Pressure Swichgage
instrument
High Coolant/ Temperature Swichgage
instrument
518PH Magnetic Switch.
SV Series Solenoid Fuel Shutoff Valve.
PB128S Emergency stop push button.
Specifications
Low Lube Oil Pressure Swichgage
instrument:
0-100 psi (0-689 kPa) [0-6.89 bar]
1/8 NPT process connection
Low Pump Pressure Swichgage instrument:
0-150 psi (1.03 MPa) [10.34 bar]
1/8 NPT process connection
High Coolant Swichgage instrument:
130-250°F (54-121°C)
48 in. (1.2 m) capillary
1/2 NPT process connection
518PH Magnetic Switch:
12 or 24 volt (specify)
SV Series Solenoid Fuel Shutoff Valve:
12 or 24 volt (specify)
Shipping Weight: 8 lbs. 8 ozs. (3.9 kgs.)
Shipping Dimensions:
15.5 x 16 x 10.5 in. (394 x 406 x 267 mm).
Warranty
A limited warranty on materials and workmanship
is given with this FW Murphy product. A copy of
the warranty may be viewed or printed by going to
www.fwmurphy.com/support/warranty.htm
IR-03063B
Revised 04-06
Catalog Section 30
(00-02-0544)
Swichgage
®
Shutdown Panels for
Irrigation Engines and Pumps
75160 Series
Ideal for Irrigation Engines
Includes Loss of Pump Discharge
Pressure and High Coolant Temperature
Swichgage Instruments
Model With Solenoid Fuel Shutoff Valve
20PW7-F-150
Pump Pressure
20P-F-100
Oil Pressure
20T-F-250
Water Temp.
518PH-12
Magnetic Switch
PB128S
Emergency Stop
Push Button
12 in. (305 mm)
5-1/2 in. (140 mm)
4-5/8 in. (117 mm)
10.130 in. (257 mm)
1/2-14 NPT
Adapter Nut
shipped loose
Dimensions (all Models)
NOTE: This is an standard schematic. If non-standard components are specified,
this schematic may not exactly reflect your panel.