NETGEAR 2100 Computer Drive User Manual


 
ReadyNAS 2100 User Manual
Managing Your ReadyNAS 2100 2-25
v1.1, June 2009
SNMP
If you use an SNMP management system such as HP OpenView or CA UniCenter to monitor
devices on your network, you can set up the ReadyNAS 2100 device to work with this
infrastructure.
To set up SNMP service:
1. Select the SNMP tab to display the SNMP settings.
2. Select the Enable SNMP service check box. You can leave the Community field set to
public, or specify a private name if you have opted for a more segregated monitoring scheme.
3. Enter a host name or an IP address in the Trap destination field. This is where all trap
messages will be sent. The following system events generate a trap:
Abnormal power voltage
Abnormal board enclosure temperature
•Fan failure
UPS connected
UPS detected power failure
RAID disk sync started and finished
RAID disk added, removed, and failure
Snapshot invalidated
4. If you wish to limit SNMP access to only a secure list of hosts, specify the hosts in the Hosts
allowed access field.
Figure 2-26