Configuring QoS 5-6
v1.0, October 2008
Ingress Rate Limit – Enter the rate limit in kilobits per second. The possible field range is
3500 to the maximum port speed. GE (Gigabit Ethernet) ports have a maximum speed of
1000000 kilobits per second. The field default value is 3500.
Egress Shaping Rates Status – Select whether egress shaping is defined on the interface.
The possible field values are:
Enable – Enable egress shaping rate on the interface.
Disable – Disable egress shaping rate on the interface. This is the default value.
Egress Shaping Rates CIR – Enter the Egress Shaping Committed Information Rate
(CIR) in kilobits per second. The possible field range is 64 to 1000000 for GE ports.
Egress Shaping Rates CbS – Enter the Egress Shaping Committed Burst Size (CbS) in
bytes per second. The possible field range is 4KB to 16MB.
2. Select the interface.
3. Choose either Enable or Disable in the Ingress Rate Limit Status provided field in the first
row.
4. If you selected Enable in the Ingress Rate Limit Status field, enter the Ingress Rate Limit in
the provided field in the first row.
5. Choose either Enable or Disable in the Egress Shaping Rate Status provided field in the first
row.
6. If you selected Enable in the Egress Shaping Rate Status field, enter the Egress Shaping
Rates CIR and CbS in the provided fields in the first row.
7. Click APPLY to update the device.
Advanced
The CoS Advanced menu contains the following options:
“CoS to Queue Mapping”
“DSCP to Queue Mapping”
CoS to Queue Mapping
The CoS to Queue Mapping screen contains fields for mapping CoS values to traffic queues.