GS700AT Smart Switch Software Administration Manual
Monitoring the Switch 7-3
v1.0, October 2008
Enable – Enable device logs.
2. Select either Enable or Disable as the Logging State in the provided field.
3. Click APPLY to update the device.
Log Filter
To configure log filters:
1. Click Monitoring > Logs > Log Filter. The Log Filter screen displays:
The Log Filter screen contains the following fields:
RAM Logs – Select the minimum message severity level to appear in the RAM Log.
The
following are the available message severity levels:
Emergency – The highest warning level. If the device is down or not functioning
properly, an emergency log message is saved to the specified logging location.
Alert – The second highest warning level. An alert log is saved, if there is a serious
device malfunction; for example, all device features are down.
Critical – The third highest warning level. A critical log is saved if a critical device
malfunction occurs; for example, two device ports are not functioning, while the rest
of the device ports remain functional.
Error – A device error has occurred; for example, if a single port is offline.
Warning – The lowest level of a device warning. The device is functioning, but an
operational problem has occurred.
Notice – Provides device information.
Informational – Provides device information.
Figure 7-2