CONNECTING THE UNIT
For 300 Series fiber units, remove the dust cap from the fiber optic connectors and connect the fiber
optic cables. For Fiber Optic ports, the TX port on the near station should be connected to the RX port
of the far end station, and the RX port should be connected to the TX port of the far end station.
For 10Base-T ports, plug a Category 3 (or greater) twisted pair cable into the RJ45 connector. For
100Base-T ports, plug a Category 5 (or greater) twisted pair cable into the RJ45 connector. Connect the
other end to the far end station. Verify that the LNK LED’s are ON once the connection has been
completed. To connect any other port to another Switch or Repeater, use a standard Cat5 straight
through or crossover cable.
TROUBLESHOOTING
1. Make sure the (Power LED) is ON.
2. Verify that Link LED’s are ON for connected ports.
3. Verify cabling used between stations.
4. Verify that cabling is Category 5 (or greater) for 100Mbit Operation.
5. Verify TX is connected to far end RX and vise versa (fiber optic units only).
SUPPORT
Contact N-TRON Corp. at:
TEL: 251-342-2164
FAX: 251-342-6353
www.n-tron.com
support@n-tron.com
FCC STATEMENT
This product complies with Part 15 of the FCC-A Rules.
Operation is subject to the following conditions:
(1) This device may not cause harmful Interference
(2) This device must accept any interference received, including interference that may cause undesired
operation.