COUNTER SECTION
Counter type 82C54
Configuration Two 82C54 devices. 3 down counters per 82C54, 16 bits each
82C54A:
Counter 0 - ADC residual sample counter.
Source: ADC Clock.
Gate: Internal programmable source.
Output: End-of-Acquisition interrupt.
Counter 1 - ADC Pacer Lower Divider
Source: 10 MHz oscillator
Gate: Tied to Counter 2 gate, programmable source.
Output: Chained to Counter 2 Clock.
Counter 2 - ADC Pacer Upper Divider
Source: Counter 1 Output.
Gate: Tied to Counter 1 gate, programmable source.
Output: ADC Pacer clock (if software selected), available at user
connector.
82C54B:
Counter 0 - Pretrigger Mode
Source: ADC Clock.
Gate: External trigger
Output: End-of-Acquisition interrupt.
Counter 0 - User Counter 4 (when in non-Pretrigger Mode)
Source: User input at 100-pin connector (CLK4) or internal
10 MHz (software selectable)
Gate: User input at 100-pin connector (GATE4).
Output: Available at 100-pin connector (OUT4).
Counter 1 - User Counter 5
Source: User input at 100-pin connector (CLK5).
Gate: User input at 100-pin connector (GATE5).
Output: Available at 100-pin connector (OUT5).
Counter 2 - User Counter 6
Source: User input at 100-pin connector (CLK6).
Gate: User input at 100-pin connector (GATE6).
Output: Available at 100-pin connector (OUT6).
Clock input frequency 10 MHz max
High pulse width (clock input) 30 ns min
Low pulse width (clock input) 50 ns min
Gate width high 50 ns min
Gate width low 50 ns min
Input low voltage 0.8 V max
Input high voltage 2.0 V min
Output low voltage 0.4 V max
Output high voltage 3.0 V min
36