271
Appendix F
Making the Cable for Connecting a PLC
Refer to the following when making a cable for connecting the Support Tool.
Assembly of Connecting Cables
Wiring should be carried out in one of the following ways, depending on the type of RS-232C connector.
25-pin Connector
Note Connect a shielding wire to the connector hood of the connectors both at the personal computer end
and the PT end.
Use the following recommended products when making the connecting cable.
9-pin Connector
Note Connect a shielding wire to the connector hood of the connectors both at the personal computer end
and the PT end.
SD
RD
RS
CS
SG
FG
Personal computer Connector for peripheral devices on PT
Shielding wire
Connector hood
2
3
4
5
7
1
SD
RD
RS
CS
SG
2
3
4
5
9
Connector hood
Name Model Remarks
Connector XM2D-2501 25-pin, made by OMRON, for personal computer side
XM2A-0901 9-pin, made by OMRON, for PT side
Connector hood XM2S-2511 25-pin, made by OMRON, for personal computer side
XM2S-0911 9-pin, made by OMRON, for PT side
Cable AWG28×5P IFVV-SB Multi-core shielded cable, made by Fujikura Ltd.
CA-MA-VV-SB 5P×28AWG Multi-core shielded cable, made by Hitachi Cable, Ltd.
RD
SD
RS
CS
SG
Personal computer Connector for peripheral devices on PT
Shielding wire
Connector hood
2
3
7
8
5
SD
RD
RS
CS
SG
2
3
4
5
9
Connector hood