OPTI-UPS PS1500C Power Supply User Manual


 
26.
Specifications
PS1000C / PS1250C / PS1500C / PS2000C / PS3000C
* PS1000C / PS1250C /
PS1500C / PS2000C /
PS3000C
windows
2000 / XP
2003 / Vista
Front Panel
Rear Panel
PS1000C / PS1250C / PS1500C /
PS2000C / PS3000C
PS1000C / PS1250C / PS1500C / PS2000C
Load
Buck AVR
Line Normal
Boost AVR
On / Test
OFF
Battery
Capacity
Overload
Backup
Replace
Battery
USB
TEL / Modem
Output
AC Input
RS232
SNMP
Port
Battery Pack
Input
Circuit
Breaker
USB
TEL / Modem
Output
AC Input
RS232
SNMP
Port
Battery Pack
Input
Circuit
Breaker
RS232
TEL / Modem
SNMP
Port
Output
Input
Circuit
Breaker
USB
Battery
Pack
PS3000C
Sine Wave
Line Interactive
UPS Series
On Line UPS
Series
AVR Series
Networking
Series
Inverter Series
Surge Series
Green Power
Series
Standby UPS
Series
PS1000C PS1250C PS1500C PS2000C PS3000C
100 / 110 / 120 Vac or 220 / 230 / 240 Vac +/-25% (PS3000C 220V/230V/240V only)
50 or 60Hz +/-5% (auto sensing)
Pure Sine wave output at nominal +/-5%
50 or 60Hz +/-0.5%
3,500 meters max. elevation, 0%-95% humidity non-condensing, Temperature: 0-40ºC
<45dBA (1 meter from surface)
15,000 meters max. elevation
1000VA/600W 1250VA/750W 1500VA/900W 2000VA/1200W 3000VA/1800W
30 min. 35 min. 40 min. 45 min. 90 min.
Line-Interactive
Pure Sine Wave
(in)
(mm)
Dimension (Physical/ Packing)
(L x W x H)
35.0/36.1 33.1/36.2 33.1/36.2 62.6/66.1
13.9/15.3 15.0/16.4 15.0/16.4 28.4/30.3
14.9 x 5.5 x 7.9 / 19.2 x 10.6 x 12.8
378 x 140 x 201 / 487 x 270 x 326
17.7 x 6.7 x 8.9 / 22.0 x 11.8x 14.2
450 x 170 x 226 / 560 x 300 x 360
12V / 7.2AH x 2
12V / 34W x 2
12V / 34W x 4
AVR automatically increases output voltage 15% above input voltage when input voltage
drops lower than 9% from nominal. AVR decreases output voltage 13% below input voltage
when input voltage rises higher than 9% from nominal.
Typology
On-battery Output Wave Form
INPUT
Capacity
Voltage
Frequency
OUTPUT
Voltage (on battery)
Frequency (on battery)
Voltage Regulation AVR
PROTECTION & FILTERING
Spike Protection
Unit Input
EMI/RFI filter
Overload protection
Transfer Time
Short Circuit
BATTERY
Type
User Replaceable Battery
Typical Recharge Time
Protection
Back-up Time
(one PC and one 17” LCD monitor)
ALARM
Battery Back-Up
Battery Low
Overload
INTERFACE
RS-232 Interface
USB
Dry Contact
SNMP Slot
ENVIRONMENT
Ambient Operation
Audible noise
Storage condition
PHYSICAL
Weight (Net/Gross) (lbs)
(Kg)
420 Joules (IEC models) / 225 Joules (NEMA models), 8/20μs
Circuit breaker protection
10dB at 0.15MHz, 50dB at 30MHz
UPS automatic shutdown if overload exceeds 110% of nominal
for 20 second and 125% for 2 seconds
6~8 milliseconds (typical), including detection time
UPS output cut off immediately or input circuit breaker protection
Hot swappable, Sealed, Maintenance-free lead acid
4 hours (to 90% of full capacity)
Automatic self-test & discharge protection,
“Replace battery” indicator
Slow beeping sound (about 0.25Hz)
Rapid beeping sound (about 1.00Hz)
Continuous beeping sound
Yes
Yes
Sends AC fail and battery low singals, and receives shutdown signal from computer
Yes