69
[Preparation]
Preparation
<Remarks>
After changing the parameter value and pressing , the content will be reflected in the control.
Do not extremely change the parameter value which change might affect the motor movement very much
(especially velocity loop or position loop gains).
Press or to select parameter No. to be referred/set.
Parameter No. (Hexadecimal No.)
<Note>
For parameters which place is displayed with “ ”, the content
changed and written to EEPROM becomes valid after turning off
the power once.
(2)
Press or to set up the value of parameter.
Value increases with decreases with .
(1) You can change the decimal point with ,
then shift the digit for data change.
Press to shift to arrowed direction.
Press to shift to reversed direction.
You can change the value which digit has a flashing decimal point.
Parameter value
<Note>
Each parameter has a limit in number of
places for upper-shifting.
After setting up parameters, return to SELECT mode, referring to structure of each mode (P.60 and 61).
Press once after pressing from
initial status of LED to change the display to
Parameter setup mode,
Press to change to EXECUTION display of
Parameter Setup Mode
Operation at SELECTION display
Operation at EXECUTION display