How to Use the Front Panel and Console
Servo-ON status
Preparation step 2 for trial run
Preparation step 1 for trial run
Turns to Servo-OFF
by pressing .
After the Servo-ON of preparation step 2 for trial run,
the motor runs at the preset speed with Pr3D (JPG speed) to CCW direction by pressing CW by
pressing .
The motor stops by pressing .
After finished trial running, return to SELECTION display, referring to structure of each mode (P.60 and 61).
<Notes>
Set up torque limit input invalidation (Pr03) to 1, run-inhibit input invalidation (Pr04) to 1 and ZEROSPD
input (Pr06) to 0.
If SRV-ON becomes valid during trial run, the display changes to which is normal run through
external command.
<Caution>
If such trouble as disconnection of cable or connector occurs during trial run, the motor makes 
over-run for maximum 1 sec. Pay an extra attention for securing safety.
Not a Servo-Ready.
Or SRV-ON signal is not entered.
Not a servo-ready status.
(Shuts off the main when error occurs.)
Press to call for 
EXECUTION DISPLAY of
Then keep pressing until 
the display of Console (LED) 
changes to .
Then keep pressing 
until the display of LED 
changes to .
Press four time after pressing , 
to setup auxiliary function mode, 
then with , make a display to
Keep pressing (approx. 5 sec) 
to shift the decimal point toward 
left as the left fig. shows.
“ ”
increases by 
pressing (approx. 5sec) 
as the left fig. shows.
Procedure for Trial Run
When you use the console, insert the console connector to CN X4 of the driver securely and turn on the
driver power.
Operation at SELECTION display
Operation at EXECUTION display