Panasonic MA2Z785 (MA785) Switch User Manual


 
Schottky Barrier Diodes (SBD)
1
Publication date: April 2004 SKH00038BED
MA2Z785 (MA785)
Silicon epitaxial planar type
For super high speed switching
For small current rectification
Features
High-density mounting is possible
Forward current (Average) I
F(AV)
= 100 mA rectification is
possible
Optimum for high frequency rectification because of its short
reverse recovery time t
rr
Low forward voltage V
F
and good rectification efficiency
Reverse voltage V
R
= 50 V is guaranteed
Absolute Maximum Ratings T
a
= 25°C
Marking Symbol: 2E
Parameter Symbol Rating Unit
Reverse voltage V
R
50 V
Repetitive peak reverse voltage V
RRM
50 V
Peak forward current I
FM
300 mA
Forward current (Average) I
F(AV)
100 mA
Non-repetitive peak forward I
FSM
1A
surge current
*
Junction temperature T
j
125 °C
Storage temperature T
stg
55 to +125 °C
Parameter Symbol Conditions Min Typ Max Unit
Forward voltage V
F
I
F
= 100 mA 0.55 V
Reverse current I
R
V
R
= 50 V 30 µA
Terminal capacitance C
t
V
R
= 0 V, f = 1 MHz 25 pF
Reverse recovery time
*
t
rr
I
F
= I
R
= 100 mA 3.0 ns
I
rr
= 0.1 I
R
, R
L
= 100
Electrical Characteristics T
a
= 25°C ± 3°C
Bias Application Unit (N-50BU)
90%
Pulse Generator
(PG-10N)
R
s
= 50
Wave Form Analyzer
(SAS-8130)
R
i
= 50
t
p
= 2 µs
t
r
= 0.35 ns
δ = 0.05
I
F
= 100 mA
I
R
= 100 mA
R
L
= 100
10%
Input Pulse Output Pulse
I
rr
= 0.1 I
R
t
r
t
p
t
rr
V
R
I
F
t
t
A
Unit: mm
1: Anode
2: Cathode
EIAJ: SC-76 SMini2-F1 Package
1.25
±0.1
0.7
±0.1
2.5
±0.2
1.7
±0.1
0.4
±0.1
0 to 0.1
(0.15)
0.16
0.5
±0.1
1
2
+0.1
–0.06
0.35
±0.1
0 to 0.1
Note)
*
: The peak-to-peak value in one cycle of 50 Hz sine wave (non-repetitive)
Note) 1. Measuring methods are based on JAPANESE INDUSTRIAL STANDARD JIS C 7031 measuring methods for diodes.
2. This product is sensitive to electric shock (static electricity, etc.). Due attention must be paid on the charge of a human body
and the leakage of current from the operating equipment.
3. Absolute frequency of input and output is 200 MHz. 4.
*
: t
rr
measurement circuit
Note) The part number in the parenthesis shows conventional part number.