Panasonic MA3X704 (MA704) Network Card User Manual


 
Schottky Barrier Diodes (SBD)
1
Publication date: April 2004 SKH00073CED
Parameter Symbol Rating Unit
Reverse voltage
MA3X704 V
R
15 V
MA3X704A
30
Maximum peak
MA3X704 V
RM
15 V
reverse voltage
MA3X704A
30
Peak forward current
I
FM
150 mA
Forward current I
F
30 mA
Junction temperature T
j
125 °C
Storage temperature T
stg
55 to +125 °C
MA3X704 (MA704), MA3X704A (MA704A)
Silicon epitaxial planar type
For switching
For wave detection
Features
Low forward voltage V
F
and good wave detection efficiency η
Small temperature coefficient of forward characteristic
Small reverse current I
R
Absolute Maximum Ratings T
a
= 25°C
Parameter Symbol Conditions Min Typ Max Unit
Forward voltage V
F1
I
F
= 1 mA 0.4 V
V
F2
I
F
= 30 mA 1.0
Reverse current MA3X704 I
R
V
R
= 15 V 200 nA
MA3X704A V
R
= 30 V 300
Terminal capacitance C
t
V
R
= 1 V, f = 1 MHz 1.5 pF
Reverse recovery time
*
t
rr
I
F
= I
R
= 10 mA 1.0 ns
I
rr
= 1 mA, R
L
= 100
Detection efficiency η V
IN
= 3 V
(peak)
, f = 30 MHz 65 %
R
L
= 3.9 k, C
L
= 10 pF
Electrical Characteristics T
a
= 25°C ± 3°C
Bias Application Unit (N-50BU)
90%
Pulse Generator
(PG-10N)
R
s
= 50
Wave Form Analyzer
(SAS-8130)
R
i
= 50
t
p
= 2 µs
t
r
= 0.35 ns
δ = 0.05
I
F
= 10 mA
I
R
= 10 mA
R
L
= 100
10%
Input Pulse Output Pulse
I
rr
= 1 mA
t
r
t
p
t
rr
V
R
I
F
t
t
A
Marking Symbol
MA3X704: M1K MA3X704A: M1L
Internal Connection
12
3
Unit: mm
1: Anode
2: N.C.
3: Cathode
EIAJ: SC-59 Mini3-G1 Package
0.40
+0.10
–0.05
(0.65)
1.50
+0.25
–0.05
2.8
+0.2
–0.3
2
1
3
(0.95) (0.95)
1.9
±0.1
2.90
+0.20
–0.05
0.16
+0.10
–0.06
0.4±0.2
10˚
0 to 0.1
1.1
+0.2
–0.1
1.1
+0.3
–0.1
Note) 1. Measuring methods are based on JAPANESE INDUSTRIAL STANDARD JIS C 7031 measuring methods for diodes.
2. This product is sensitive to electric shock (static electricity, etc.). Due attention must be paid on the charge of a human body
and the leakage of current from the operating equipment.
3. Absolute frequency of input and output is 2 GHz.
4.
*
:t
rr
measurement circuit
Note) The part numbers in the parenthesis show conventional part number.
This product complies with the RoHS Directive (EU 2002/95/EC).