Panasonic MA3Z792E Network Card User Manual


 
Schottky Barrier Diodes (SBD)
1
Publication date: April 2004 SKH00097BED
MA3Z792D (MA792WA), MA3Z792E (MA792WK)
Silicon epitaxial planar type
For super high speed switching
For small current rectification
Features
Two MA3Z792 (MA792) is contained in one package
Forward current (Average) I
F(AV)
= 100 mA rectification is possible
Optimum for high frequency rectification because of its short
reverse recovery time t
rr
Low forward voltage V
F
and good rectification efficiency
Absolute Maximum Ratings T
a
= 25°C
Parameter Symbol Conditions Min Typ Max Unit
Forward voltage V
F
I
F
= 100 mA 0.55 V
Reverse current I
R
V
R
= 30 V 15 µA
Terminal capacitance C
t
V
R
= 0 V, f = 1 MHz 20 pF
Reverse recovery time
*
t
rr
I
F
= I
R
= 100 mA 2 ns
I
rr
= 10 mA, R
L
= 100
Electrical Characteristics T
a
= 25°C ± 3°C
Parameter Symbol Rating Unit
Reverse voltage V
R
30 V
Repetitive peak reverse voltage V
RRM
30 V
Forward current Single I
F
100 mA
Double
*
1
70
Peak forward Single I
FM
300 mA
current Double
*
1
200
Non-repetitive peak forward I
FSM
1A
surge current
*
2
Junction temperature T
j
125 °C
Storage temperature T
stg
55 to +125 °C
Bias Application Unit (N-50BU)
90%
Pulse Generator
(PG-10N)
R
s
= 50
Wave Form Analyzer
(SAS-8130)
R
i
= 50
t
p
= 2 µs
t
r
= 0.35 ns
δ = 0.05
I
F
= 100 mA
I
R
= 100 mA
R
L
= 100
10%
Input Pulse Output Pulse
I
rr
= 10 mA
t
r
t
p
t
rr
V
R
I
F
t
t
A
SMini3-F1 Package
Marking Symbol
MA3Z792D: M3Y MA3Z792E: M3Z
Internal Connection
12
3
12
3
D
E
MA3Z792D MA3Z792E
1 Cathode 1 Anode 1
2 Cathode 2 Anode 2
3 Anode Cathode
Unit: mm
0.3
2.0
±0.2
1.3
±0.1
(0.65)
1
3
2
(0.65)
0.9
±0.1
2.1
±0.1
1.25
±0.1
0 to 0.1
(0.15)
(0.425)
+0.1
–0
0.15
+0.1
–0.05
Note) 1. Measuring methods are based on JAPANESE INDUSTRIAL STANDARD JIS C 7031 measuring methods for diodes.
2. This product is sensitive to electric shock (static electricity, etc.). Due attention must be paid on the charge of a human body
and the leakage of current from the operating equipment.
3. Absolute frequency of input and output is 250 MHz.
4.
*
: t
rr
measurement circuit
Note) The part numbers in the parenthesis show conventional part number.
Note)
*
1: Value of each diode in double diodes used.
*
2: The peak-to-peak value in one cycle of 50 Hz sine wave (non-repetitive)
This product complies with the RoHS Directive (EU 2002/95/EC).