Panasonic MA6X718 (MA718) Switch User Manual


 
Schottky Barrier Diodes (SBD)
1
Publication date: April 2004 SKH00112BED
MA6X718 (MA718)
Silicon epitaxial planar type
For switching
For wave detection
Features
Three isolated elements are contained in one package, allowing
high-density mounting
Two MA3X704A (MA704A) is contained in one package (of a
type in the same direction)
Forward voltage V
F
, optimum for low voltage rectification
Optimum for high frequency rectification because of its short
reverse recovery time t
rr
Absolute Maximum Ratings T
a
= 25°C
Parameter Symbol Rating Unit
Reverse voltage V
R
30 V
Peak forward current
*
I
FM
150 mA
Forward current
*
I
F
30 mA
Junction temperature T
j
125 °C
Storage temperature T
stg
55 to +125 °C
Internal Connection
Marking Symbol: M2N
Parameter Symbol Conditions Min Typ Max Unit
Forward voltage V
F1
I
F
= 1 mA 0.4 V
V
F2
I
F
= 30 mA 1.0
Reverse current I
R
V
R
= 30 V 1 µA
Terminal capacitance C
t
V
R
= 1 V, f = 1 MHz 1.5 pF
Reverse recovery time
*
t
rr
I
F
= I
R
= 10 mA 1.0 ns
I
rr
= 1 mA , R
L
= 100
Detection efficiency η V
IN
= 3 V
(peak)
, f = 30 MHz 65 %
R
L
= 3.9 k, C
L
= 10 pF
Electrical Characteristics T
a
= 25°C ± 3°C
654
123
Bias Application Unit (N-50BU)
90%
Pulse Generator
(PG-10N)
R
s
= 50
Wave Form Analyzer
(SAS-8130)
R
i
= 50
t
p
= 2 µs
t
r
= 0.35 ns
δ = 0.05
I
F
= 10 mA
I
R
= 10 mA
R
L
= 100
10%
Input Pulse Output Pulse
I
rr
= 1 mA
t
r
t
p
t
rr
V
R
I
F
t
t
A
Unit: mm
1 : Cathode 1
2 : Cathode 2
3 : Cathode 3
4 : Anode 3
5 : Anode 2
6 : Anode 1
EIAJ : SC-74 Mini6-G1 Package
2.90
1.9
±0.1
0.16
+0.10
–0.06
2.8
+0.2
–0.3
1.1
+0.3
–0.1
1.1
0 to 0.1
+0.2
–0.1
1.50
(0.65)
0.4
±0.2
+0.25
–0.05
(0.95)
0.30
+0.10
–0.05
0.50
+0.10
–0.05
(0.95)
654
132
+0.20
–0.05
10˚
Note)
*
: Value for single diode
Note) 1. Measuring methods are based on JAPANESE INDUSTRIAL STANDARD JIS C 7031 measuring methods for diodes.
2. This product is sensitive to electric shock (static electricity, etc.). Due attention must be paid on the charge of a human body
and the leakage of current from the operating equipment.
3. Absolute frequency of input and output is 2 GHz.
4.
*
: t
rr
measurement circuit
Note) The part number in the parenthesis shows conventional part number.