6/49
2.15. VOLUME +
Hexadecimal 02h 41h 55h 55h 03h
Character A U U
Response (Callback)
In the period when the command can be accepted
Hexadecimal 02h 41h 55h 55h 03h
Character A U U
Acceptability
SECURITY STANDBY NO SIGNAL
AV MUTE
REMOTE
× △ × × ○
Note:
• During STANDBY, this command is available only when IN STANDBY MODE is ON.
2.16. VOLUME -
Hexadecimal 02h 41h 55h 44h 03h
Character A U D
Response (Callback)
In the period when the command can be accepted
Hexadecimal 02h 41h 55h 44h 03h
Character A U D
Acceptability
SECURITY STANDBY NO SIGNAL
AV MUTE
REMOTE
× △ × × ○
Note:
• During STANDBY, this command is available only when IN STANDBY MODE is ON.
2.17. INDEX-window
Hexadecimal 02h 4Fh 49h 58h 03h
Character O I X
Response (Callback)
In the period when the command can be accepted
Hexadecimal 02h 4Fh 49h 58h 03h
Character O I X
Acceptability
SECURITY STANDBY NO SIGNAL
AV MUTE
REMOTE
× × × × ○
2.18. DIGITAL ZOOM +
Hexadecimal 02h 44h 5Ah 55h 03h
Character D Z U
Response (Callback)
In the period when the command can be accepted
Hexadecimal 02h 44h 5Ah 55h 03h
Character D Z U
Acceptability
SECURITY STANDBY NO SIGNAL
AV MUTE
REMOTE
× × × × ○
2.19. DIGITAL ZOOM -
Hexadecimal 02h 44h 5Ah 44h 03h
Character D Z D
Response (Callback)
In the period when the command can be accepted
Hexadecimal 02h 44h 5Ah 44h 03h
Character D Z D
Acceptability
SECURITY STANDBY NO SIGNAL
AV MUTE
REMOTE
× × × × ○