INTERFACE
Item Setting
Description of setting
No. Item No. Item
200 ID SEL 0000 OTHER
0001 DVCPRO ™™
201 LOCAL ENA 0000 DIS
0001 ST&EJ
™™
202 OPTION MODE 0000 EDL
0001 AMU1
0002 AMU2 ™
0003 AMU3
203 BAUD RATE 0000 1200
0001 2400
0002 4800
0003 9600 ™
0004 19200
204 DATA LENGTH 0000 7
0001 8
™
205 STOP BIT 0000 1
0001 2
™
206 PARITY 0000 NON
0001 ODD ™
0002 EVEN
207 FLOW 0000 NONE
CONTROL 0001 RTSCTS ™
208 EDL FORMAT 0000 AGA850
0001 CMX340 ™
The underlined number and item are the factory settings.
DETAILED DESCRIPTION OF SET-UP MENUS
26
This selects the ID information which is to be returned to the controller.
0: 20 25H
1: The ID (F0 33H) unique to DVCPRO is returned.
This selects the switches which can be operated on the front panel when the
REMOTE/LOCAL switch is at REMOTE.
0: None of the switches or buttons can be operated.
1: Only the STOP (ALL STOP) and EJECT buttons can be operated.
This sets the EDL connector (9P) mode.
0: For dumping/loading EDL data.
1: The audio memory unit is used under the audio dubbing specifications.
2: The audio memory unit is used under the audio channel 2 fade specifications.
3: The audio memory unit is used under the audio channel 1 fade specifications.
This sets the baud rate when EDL is set for set-up menu item No.202
(OPTION MODE).
This sets the data length when EDL is set for set-up menu item No.202
(OPTION MODE).
This sets the stop bit when EDL is set for set-up menu item No.202 (OPTION
MODE).
This sets the parity when EDL is set for set-up menu item No.202 (OPTION-
MODE).
This enables or disables the flow control for the EDL data communication.
0: Flow control using RTS/CTS is disabled.
1: Flow control using RTS/CTS is enabled.
This sets the format with which EDL data is to be dumped.
0: Format common with Matsushita’s AG-A850.
1: Format common with the CMX340 editing system.
VV