Paradyne 9820 Computer Monitor User Manual


 
Monitoring
6-10
9820-A2-GB20-20
June 2000
Power Module LEDs (Model 9820-45M)
Each power module has a green LED which remains lit while power is applied
and the power module is functioning.
When the yellow front panel System PWR LED is lit, one of the power modules
has failed. The failed power module can be identified from the back of the DSU
by its unlit LED.
Table 6-8. Power Module Troubleshooting
Configuration
Symptom
What to Do
(in order, if problem persists)
One Power
Module
No front panel LEDs are
lit.
1. Verify that the receptacle in use
provides 120 Vac.
2. Verify that the power module switch is
in the On position.
3. Replace the power module. See
Replacing a Power Module
in
Chapter 12,
Hardware Maintenance
.
4. Call your service representative.
Two Power
Modules
No front panel LEDs are
lit.
1. Verify that the receptacles in use
provide 120 Vac.
2. Verify that the power module switches
are in the On position.
3. Replace the power modules. See
Replacing a Power Module
in
Chapter 12,
Hardware Maintenance
.
4. Call your service representative.
The front panel System
PWR LED is lit.
1. Check the power module LEDs from the
back of the unit and replace the failed
power module (the one whose LED is
off). See
Replacing a Power Module
in
Chapter 12,
Hardware Maintenance
.
2. Call your service representative.