Perle Systems 4030370 Server User Manual


 
188
Serial Port Profiles
Configure the following parameters:
Editing Power Management Plug Settings Field Descriptions
Configure the following parameters:
Session Strings
Controls the sending of ASCII strings to serial devices at session start as
follows;
z Send at Start—If configured, this string will be sent to the serial device
on power-up of the IOLAN or when a kill line command is issued on this
serial port. If the "monitor DSR" or "monitor DCD" options are set, the
string will also be sent when the monitored signal is raised.
Range: 0-127 alpha-numeric characters
Range: hex 0-FF
z Delay after Send—If configured, will inset a delay after the string is sent
to the device. This delay can be used to provide the serial device with time
to process the string before the session is initiated or terminated.
Default: 10 ms
Name Specify a name for the plug to make it easier to recognize and manage.
Power Up Interval Specify the amount of time, in seconds, that the RPS will wait before powering
up a plug. This can be useful if you have peripherals that need to be started in a
specific order.
Data Options: .5, 1, 2, 5, 15, 30, 60, 120, 180, 300
Default: .5 seconds
Default State Sets the default state of the plug.
Data Options: On, Off
Default: Off
Associated Port When a server or router has its console port connected to one of the serial ports
on this IOLAN and that server/router is also powered by this RPS, the
server/router serial port number should be entered here. This will give you
direct access to some RPS commands when managing that server or router
(using Telnet or SSH).