199
Serial Port Profiles
Dial In If the device is remote and will be dialing in via modem or ISDN TA, enable
this parameter.
Default: Disabled
Dial Out If you want the modem to dial a number when the serial port is started, enable
this parameter.
Default: Disabled
Dial In/Out Enable this option when you want the serial port to do either of the following:
z accept a call from a modem or ISDN TA
z dial a number when the serial port is started
Default: Disabled
MS Direct Host Specify this option when the serial port is connected to a Microsoft Guest
device.
Default: Enabled
MS Direct Guest Enable this option when the serial port is connected to a Microsoft Host device.
Default: Disabled
Dial Timeout The number of seconds the IOLAN will wait to establish a connection to a
remote modem.
Range: 1-99
Default: 45 seconds
Dial Retry The number of times the IOLAN will attempt to re-establish a connection with
a remote modem.
Range: 0-99
Default: 2
Modem The name of the predefined modem that is used on this line.
Phone The phone number to use when Dial Out is enabled.
Session Strings Controls the sending of ASCII strings to serial device at session start as
follows;
z Send at Start—If configured, this string will be sent to the serial device
on power-up of the IOLAN, or when a kill line command is issued on this
serial port. If the "monitor DSR" or "monitor DCD" options are set, the
string will also be sent when the monitored signal is raised.
Range: 0-127 alpha-numeric characters
Range: hexadecimal 0-FF
z Delay after Send - If configured, will inset a delay after the string is sent
to the device. This delay can be used to provide the serial device with time
to process the string before the session is initiated.
Default: 10 ms