An example UDP configuration is described based on the following window.
The UDP configuration window, taken from the DeviceManager, is configured to:
z UDP Entry 1
All hosts that have an IP address that falls within the range of 172.16.1.1 to 172.16.1.25
and listen to
Port 33001 will be sent the data from the serial device in UDP format. The serial
device will only receive UDP data from the hosts in that range with a source
Port of 33001. The
IOLAN will listen for data on the port value configured in the
Listen for connections on UDP
port
parameter. (10001 in above example)
z UDP Entry 2
All UDP data received from hosts that have an IP address that falls within the range of
172.16.1.20 to 172.16.1.50 and Port 33010 will be sent to the serial device. The IOLAN
will not send any data received on its serial port.
z UDP Entry 3
All hosts that have an IP Address that falls within the range of 172.16.1.75 to 172.16.1.80
and who listen to
Port 33009 will receive UDP data from the serial device. The IOLAN will
listen for messages on the port value configured in the
Listen for connections on UDP port
parameter. No UDP data will be sent to the serial device.
z UDP Entry 4
This entry is disabled since Direction is set to Disabled.
General Tab Field Descriptions
Configure the following parameters:
Listen for
connections on
UDP port
The IOLAN will listen for UDP packets on the specified port.
Default: 1000+<port-number> (for example, 10001 for serial port 1)