Chapter 2 - Installation of Monitor
This monitor is intended to be mounted in and used where NEMA 4 and NEMA 12 type
enclosures are employed. Enclosures made of heavier gauge metal work better because they won’t
deform or bend as easily when the monitor’s sealing gasket is compressed The monitor meets NEMA
4/12 sealing specifications when properly installed in an approved NEMA enclosure constructed from 14-
gauge or heavier steel. The monitor uses “U”-shaped clips and a special gasket to achieve the proper
seal.
When selecting an enclosure remember to allow adequate space around the rear of the monitor
for good air flow. Do not block air flow from below or above the monitor. If possible mount the monitor in a
vertical orientation. The monitor is designed to work in environments up to 50 degrees Centigrade.
Remember to account for heat dissipated from other equipment that may be inside the same enclosure.
To install the monitor, make a cutout according to the diagram below in one of the walls of your
NEMA enclosure. Enclosures made of heavier gauge metal work better in that they won’t deform or bend
as easily when the monitor’s sealing gasket is compressed. Next hold the monitor in place while you
install the mounting clips. Tighten the clips to the point were the back of the monitor’s front bezel just
begins to contact the front of the NEMA enclosure. The use of an adjustable torque driver is
recommended. The screws should be tightened to 8 inch-pounds. Tighten the clips in a cross pattern.
This will help to develop an even pressure on the sealing gasket. DO NOT OVER TIGHTEN AS DAMAGE
CAN RESULT IN THE MONITOR CAUSING LOSS OF SEALING INTEGRITY.
Cutout Pattern for M1900 / M1900T Monitor