Philips MIIC-201D/U Network Card User Manual


 
31
Advanced Set Up Screen
5.1.3.2 Advanced Setup
On the Advanced Setup screen you can set the following parameters:
Adapter’s Own I
2
C Slave Address
Select the I
2
C adapter’s own slave address. The adapter will acknowledge messages
sent to this slave address. The default address is 0x6E.
General Call Enable
General Call Enable allows the I
2
C adapter to respond as a slave receiver to the I
2
C
General Call Address (0x00). General Call is used by a master to broadcast an I
2
C
message to multiple devices. The default value is enabled.
I
2
C Bus Master Bit Rate
Select I
2
C Bus speed during master operations. 100kHz is standard mode. 400kHz
is fast mode. Available rates are I
2
C adapter dependant.
I
2
C Bus Time-Out
Specify how long the I
2
C adapter will wait before reporting an I
2
C Bus inter-byte
time-out (0 = no time-out, 1 to 32767 milliseconds, iPort/AI fixed at 1 second).
Enable INT Signal Monitor (on supported adapters)
Enables monitoring of the INT signal state. INT state changes are reported in the
main screen Communications Events window.