24 J693
4.1.4 System Settings
INTERNAL MODULE
1024 KB
Sets the number of 1K blocks allocated for
the internal RAM ‘D’ module. Available
memory dependent upon model; see
Appendix C.
DEFAULT MODULE
D
Sets the default module used to store files
when no module is specified;
see Appendix C.
SCALEABLE FONT
CACHE
0312 KB
Sets the number of 1K blocks allocated for
the scaleable font engine. Available memory
dependent upon model; see Appendix C.
SYMBOL SET
Selects the code page used to print single
byte fonts unless otherwise specified in DPL,
see the Programmer’s Manual.
PC_850
MULTILINGUAL
61 selectable sets, see the Programmer’s
Manual.
TIME AND DATE
Allows the user to set Time and Date.
MEDIA COUNTERS
Internal record of inches printed and time in
use.
ABSOLUTE COUNTER
Shows the number of inches printed and
number of hours the printer has been
powered ‘On’ since being set at the factory.
Not resettable by the user.
RESETTABLE
COUNTER
The number of operational hours and inches
printed from the date last reset. User may
reset.
RESET COUNTER
Resets the resettable counters to zero.
PRINT CONFIGURATION
Prints the effective configuration of the
system. In addition, if settings were changed
that require a reset to become effective, this
will be indicated with the ‘§’ symbol.
A ‘•’ symbol next to the printed item
indicates that it was changed via the host but
not saved in non-volatile memory.
(Continued next page)