Polycom KWS6000 Server User Manual


 
Configuring KIRK Base Station
12–9
Figure 12-9 Adm. Page WS:Administration/Base station page
4 In the RPN field (Radio Part Number), type the radio part number of the
base station.
The radio ID can be a number between 0 and 255. See your site planner.
Note: The default value of the RPN is equal to the base station number. It
is strongly recommended not to change this value.
5 It is possible to select Auto sync if you are deploying and want to find a
sync way for the first base station.
Note: Auto sync is only to be used in a deployment situation. When
selecting Auto sync, radio part numbers in the Primary sync. (RPN) field
and Secondary sync. (RPN) field are not taken into consideration.
6 In the Primary sync. (RPN) field, type the radio part number of the base
station, you want to synchronize on. See your site planner.
7 In the Secondary sync. (RPN) field, type the radio part number of the
base station, you want to synchronize on. See your site planner.
8 Click Save.
9 Click Restart to enable the configuration changes.
To check the sync state of the base station, refer to “Sync State of Base Station”
on page 15-26.
Configuring a KIRK Base Station Using Static IP Address
This section describes how to configure a base station using static IP address.
For information on accessing the web based Administration Page, refer to
“Accessing the Web Based Administration Page” on page 12-3.
This section contains information about: