12. TROUBLESHOOTING
Cleaning the Body of the laminator
To clean the machine body, dampen a cloth with water only and gently wipe the
machine clean.
Removing Adhesive Build Up
1. Remove the film from the laminator.
2. Use a damp (water only) cloth and a rubber gum eraser to remove
the adhesive on the Teflon (metal) and silicone rollers.
Symptom
Machine will
not turn on:
There is power, but the
rollers are not turning
after the "RUN" button is
pressed:
The unit is not heating up
Curled lamination:
Unclear lamination:
Cause
a. Power switch is in "0"
(Off) position
b. Tripped circuit breaker.
c. Blown main power fuse.
a. Safety cover is not closed.
b. Paper guide is not installed
correctly.
c. Blown motor fuse.
a. The machine is in "COLD"
mode.
b. Set temperature is lower
than the room temperature.
a. Upward curl.
b. Downward curl.
The main roller temperatures
are too low and/or lamination
speed is too fast.
Possible Solution
a. Put the power switch to
the "I" (On) position
b. Reset the circuit breaker.
c. Replace the fuse.
a. Close the safety cover to
active the safety switch.
b. Properly install the paper
guide so that the micro
switch is activated.
c. Replace the motor fuse.
a. Switch to "HOT" mode.
b. Raise the temperature
according to the
recommended film
temperature.
a. Loosen the top roll film
tension.
b. Loosen the bottom roll
film tension.
Raise the roller
temperatures and/or
lower the lamination speed.
NOTE: Rub firmly but do not scrub the rollers vigorously as this may
scratch the surface. Do not use sharp metal objects, steel wool,
or abrasive, as these may also damage the rollers.