Sanyo PLC-SW30 Projector User Manual


 
40
Lamp Replace
When the life of the projection lamp draws to an end, LAMP
REPLACE indicator lights yellow. If this indicator lights yellow,
replace the projection lamp with a new one promptly.
ORDER REPLACEMENT LAMP
Replacement Lamp can be ordered through your dealer. When ordering a projection lamp, give the following
information to the dealer.
Model No. of your projector : PLC-SW30
Replacement Lamp Type No. : POA-LMP57
(Service Parts No. 610 308 3117)
For continued safety, replace with a lamp assembly of
the same type.
Do not drop a lamp assembly or touch a glass bulb! The
glass can shatter and may cause injury.
Allow a projector to cool, for at least 45 minutes before
you open Lamp Cover. The inside of a projector can
become very hot.
POWER
LAMP
REPLACE
WARNING
INPU
TOP CONTROL
CAUTION
Turn off the projector and disconnect AC plug. Allow the
projector to cool at least for 45 minutes.
Remove the two screws with a screwdriver and pull out the
lamp assembly by grasping the handle.
1
3
Replace the lamp assembly with a new one and tighten the two
screws back into the position. Make sure that the lamp
assembly is set properly. Replace the lamp cover and tighten
the screw.
4
To remove the lamp cover, remove the screw with a screwdriver .
2
Connect the AC Power Cord to the projector and turn on the
projector.
6
Follow these steps to replace the lamp assembly.
Reset the Lamp Replace Counter.
Refer to “Lamp Replace Counter” on the next page .
5
Lamp Assembly
Handle
Lamp Cover
Note :
Do not reset the Lamp Replace Counter when the projection lamp has not
been replaced.
Screws
Screw
This indicator lights yellow when the
life of the projection lamp draws to an
end.
Lamp Replacement
Maintenance