7.4 Clear Dispenser Counter
STEP PROCEDURE
1. Record all current dip switch positions, then place all switches in the OFF
position.
2. Place the DSW2-4 in the ON or up postion.
3. Press the LINE and FEED key while simultaneously turning ON the power
switch. When the printer beeps, release the keys. The following screens will
appear.
4. Place the DSW-4 in the OFF postion and the following screen will appear.
5. Press the FEED key to display the next screen.
6. Press the LINE key trice to change the message from NONE to DIS.
7. Press the FEED key to clear the DISPENSER Counter. After a pause, the next
screen will appear.
8. Select the print label size by pressing the LINE key. The default is LARGE.
9. Press the FEED key for a test print. Press the FEED key again to stop printing.
10. Verify that the counters on the test print have reset to 0.0 km.
11. Power OFF the printer and confirm that all switches are in the OFF or down
position.
counter clear
none
factory mode
initializing
rom v00.00.00.00
maintenance mode
dipsw2-4 on->off
counter clear
Dis
print size
small large
test print
press feed key
To reset the printer to the factory settings, perform the following steps.
Caution: Resetting the printer will clear all registers.
Warning: This test activates all the heating
elements on the print head and therefore
should be used for testing purposes only with
full width labels to avoid damaging the print
head.