Page 2-2
Section 2. Configuration
SATO CL608e/CL612e Service Manual
PN 9001079
Rev. B
DSW1
ON
OFF
1 2 3 4
5 6 7 8
DSW1
ON
OFF
1 2 3 4
5 6 7 8
DSW1
ON
OFF
1 2 3 4
5 6 7 8
DSW1
ON
OFF
1 2 3 4
5 6 7 8
DSW1
ON
OFF
1 2 3 4
5 6 7 8
DSW1-4 SETTING
Off 1 Stop Bit
On 2 Stop Bits
Parity Selection (DSW1-2, DSW1-3): These switches select the type of parity used
for error detection.
Stop Bit Selection (DSW1-4): Selects the number of stop bits to end each byte
transmission.
Baud Rate Selection (DSW1-5, DSW1-6): Selects the data rate (bps) for the RS232
port.
Dip Switch Settings
Data Bit Selection (DSW1-1): This switch sets the printer to receive either 7 or 8
data bits for each byte transmitted.
RS232 Transmit/Receive Setting (located on RS232 I/F Module)
DSW1-1 SETTING
Off 8 data bits
On 7 data bits
Protocol Selection (DSW1-7, DSW1-8): Selects the flow control and status
reporting protocols.
(* Will select protocol Bi-Com 2 for M-8400 if DSW2-8 is ON)
DSW1-2 DSW1-3 SETTING
Off Off None
Off On Even
On Off Odd
On On Not Used
DSW1-5 DSW1-6 SETTING
Off Off 9600
Off On 19200
On Off 38400
On On 57600
DSW1-7 DSW1-8 SETTING
Off Off Rdy/Bsy
Off On Xon/Xoff
On Off Bi-Com 3
On On Bi-Com 4*