SATO CL608VA Printer User Manual


 
OPERATOR PANEL CL408 and CL412
The CL408/412 Operator Panel consists of one two-color (red and green) LED
indicator, two momentary contact switches, two DIP switches (a third is located on
the RS232 interface card), four adjustment potentiometers and one LCD Display. All
of these are accessible from the front of the printer, however some are not accessible
unless the front cover is open. They are used to set the printer operating parameters
and to indicate the status of the printer to the operator. After you power on the
printer, familiarize yourself with the keys and indicators as it will help you
understand the configuration process.
PRINT: Located behind the Front Access Door. Potentiometer
to adjust print darkness (fine tuning).
OFFSET: Located behind the Front Access Door. Potentiometer
to adjust amount of back/forward feed for
dispenser/cutter/tear-off bar position (+/- 3.75 mm)
PITCH: Located behind the Front Access Door. Potentiometer
to adjust home position of the label (+/- 3.75 mm).
Affects stop position of label feed, print position and
dispense position.
Note: DSW1 (RS232 Parameter Select) is located on the RS232 Interface Board.
DSW2 DSW3
LINE FEED
LCD
DISPLAY
PANEL
LABEL TAKEN
THRESHOLD
ADJUST
x
xxx
PITCHOFFSETPRINT
LABEL
TAKEN LED
OPTION
CONNECTOR
TWO-COLOR
STATUS LED
Section 2. Installation and Configuration
Page 2-149001035 Rev. ESATOCL SeriesPrinters