SATO CX208/212 Printer User Manual


 
Expanded Memory Function
Graphics, PCX Store
Command Structure <ESC>PIaaa,bbbbb,{data}
aaa = Storage area number (001 thru 999)
bbbbb = Size of PCX file in bytes
{data} = Data
Example: <ESC>PI001,32000,{data}
Placement: This command must be placed within its own data
stream
Default: None
Command Function To store for later printing a PCX graphic file in Expanded Memory.
Printer Input BASIC Program to Download a PCX file to Expanded Memory Section
#1 (first 2MB installed).
Printer Output There is no printer output as a result of this command. See <ESC>PY
PCX Graphics Recall command.
Special Notes: 1. This command requires Expanded Memory option. See your
SATO representative for details.
2. Graphics cannot be stored as part of a format.
3. Only black and white PCX files can be stored.
4. The file size specified by this command is the DOS file size in
bytes.
Page 78 PN 9001092 Rev. A SATO CX208/212 Printers
CX208/212 Programming Guide