SATO CX208/212 Printer User Manual


 
Custom Protocol Command Codes
Download
Command Structure <ESC>LD,a,b,c,d,e,f,g,h,i
a = Replacement character for STX in ASCII or hex format
b = Replacement character for ETX in ASCII or hex format
c = Replacement character for ESC in ASCII or hex format
d = Replacement character for ENQ in ASCII or hex format
e = Replacement character for CAN in ASCII or hex format
f = Replacement character for NULL or ~ in ASCII or hex
format
g = Replacement character for OFFLINE in ASCII or hex
format
Example: <ESC>LD,{,},%,#,&,*,~,0,0
Placement: Immediately following the <ESC>A Start command and
in an independent data stream.
Default: Standard Protocol command Codes
Command Function Allows the user to defines custom Protocol Command codes.
Printer Input
Printer Output A Protocol Command code status label will be printed as a result of
the a successful download of a custom set of Protocol Command
codes.
Special Notes 1. Commas must be used to separate the parameters. If a parameter
is omitted between two commas, the default Non-Standard
Protocol Command codes for that parameter will be used.
Page 91 PN 9001092 Rev. A SATO CX208/212 Printers
CX208/212 Programming Guide