SECO-LARM USA ST-2406-10AQ Power Supply User Manual


 
Model # DC Voltage Current (continuous) Current (peak) Current Output (maximum charge) PCB Size
6, 12 1.5A 2.0A 6 V = 200mA, 12 V = 400mA 2
7
/
8
x 2
1
/
4
” x 1” (73 x 57 x 25 mm)
6, 12, 24 1.5A 2.0A 6 V = 180mA, 12 V = 350mA, 24 V = 700mA 2
7
/
8
x 2
1
/
2
” x 1
3
/
8
(73 x 64 x 35 mm)
6, 12, 24 2.5A 3.0A 6 V = 180mA, 12 V = 350mA, 24 V = 700mA 3
3
/
8
x 2
7
/
8
” x 1
5
/
16
(81 x 73 x 33 mm)
6, 12, 24 4.0A 5.0A 6 V = 180mA, 12 V = 350mA, 24 V = 700mA 3
3
/
4
x 2
7
/
8
” x 1
9
/
16
(95 x 73 x 40 mm)
6, 12, 24 7.0A 7.5A 6 V = 180mA, 12 V = 350mA, 24 V = 700mA 5
1
/
2
x 5
1
/
8
” x 2
11
/
64
(140 x 130 x 55 mm)
6, 12, 24 9.0A 10.0A 6 V = 180mA, 12 V = 350mA, 24 V = 700mA 5
1
/
2
x 5
1
/
8
” x 2
11
/
64
(140 x 130 x 55 mm)
Note: Products with model number that ends with "Q"or have a green “Q” sticker represents RoHS compliant products.
ST-2406-2AQ shown
ENFORCER
®
Installation Manual
ST-series
Power Supplies/Chargers
Features:
Automatic recharging of back-up batteries.
Several models to choose from.
Programmable DC voltage output.
Built-in battery short-circuit protection.
Fused output for a regulated charge.
Automatic switch-over to the backup battery if main power is lost or cut.
LEDs indicate power status.
Includes foam tape and battery leads for easy installation.
Regulated and filtered output voltage.
What it is:
SECO-LARM’s ST-series of power supplies/chargers ensure that alarm systems and access control systems always have
enough power to do their job. Protected by fused output, input polarity protection diodes, and back-up battery polarity
reverse protection, these power supplies/chargers can be used to maximize the security and efficiency of nearly any alarm
or access control installation.
Fused Output:
The ST-1206-1.5AQ comes with a 3A fuse. The ST-2406-2AQ, ST-2406-3AQ, and ST-2406-5AQ models come with a 5A
fuse. The ST-2406-7AQ and ST-2406-10AQ come with a 10A fuse. Use only the correct fuses to prevent short circuits
and damage to the power supplies/chargers or the alarm access control panel.
WARNING:
Connect these power supplies/chargers only to a rechargeable back-up battery. Use of a non-rechargeable back-up
battery could result in damage to the power supplies/chargers or the alarm access control panel, as well as leakage or
explosion of the battery.
Installation:
1. Mount the PC board in the desired location or enclosure. It must be easily accessible for future servicing.
2. DC Power Output Setting:
a. To program ST-1206-1.5AQ DC voltage output:
1. 6VDC — Cut the wire loop, and connect to a 12VAC/20VA transformer.
INSULATE THE CUT WIRE LEADS so that they do not come in contact with the power supplies/chargers.
2. 12VDC — Leave the wire loop uncut, and connect to a 16VAC/40VA transformer.
ST-1206-1.5AQ
ST-2406-2AQ
ST-2406-3AQ
ST-2406-5AQ
ST-2406-7AQ
ST-2406-10AQ
b. To program ST-2406 Series DC voltage output:
1. Set the desired DC output voltage ( 6, 12, or 24 VDC ) of the power supply using the DIP switch.
See Table 2.
2. The default voltage output setting is 12 VDC.