Sony ER-A410 Cash Register User Manual


 
96
Unit prices
The preset amount will work as the unit price for the “Preset” type and as the HALO amount for the
“Open” type. In the case of the “Open” type, zero preset prevents amount entry and a 9999.99
preset is the maximum limitation. In the case of the “Preset” type zero and 9999.99 preset have no
special meaning. (i.e. 0 amount preset is available.)
Programming “$1.25” for PLU 1
Base quantity
Programming “12” for PLU 2
Base qty
1211
.@
2
@
12
t
Ç
PrintKey operation
Example
1211
.
@ @t
Ç
PLU code
(max. 5 digits)
Base qty
(max. 2 digits)
To program any PLU/UPC
To program zero
To program for the following PLU/UPC
Ä
UPC code
(6 to 13 digits)
Procedure
Direct1211
PGM 2PGM 1
Unit price
1210
.@
1
@
125
t
t
Ç
PrintKey operation
Example
Note
Ç
PLU code
(max. 5 digits)
To program for the following PLU/UPC
To program any PLU/UPC
To program zero
t
Unit price 1
(max. 6 digits)
t
To program zero
Unit price 2
(max. 6 digits)
1210
.
@
@
When the unit price 2 is disabled.
Ä
UPC code
(6 to 13 digits)
Procedure
Direct1210
PGM 2PGM 1
When the price
level 2 is enabled.
ER-A410/A420(SEC)-3 03.12.22 0:18 PM Page 96