Sun Microsystems 5000 Switch User Manual


 
Flow Diagrams for Troubleshooting 10-5
10
10.4 Defective I/O Interface Board
Interface boards are hot-pluggable in many instances.
Figure 10-4 Replacing I/O Interface
INDICATION
System error message or
LED code identifies a
specific board or I/O
problem
Board not identified or
intermittent problem
Begin
End
TEST/PROCEDURE
Locate indicated board.
Check LEDs on boardto verify ASR
has deactivated the board.
Replace the board or device.
Board is not active until system is
booted.
Check /var/adm/messages
Run SunVTS to test suspected
boards, CPUs, SIMMs, power
supplies, other devices.
Check I/O cable connections.
Locate defective SCSI device with
probe-scsi-all (OpenBoot
command)
Check related modular power
supply.
REFERENCE
LED code must be Off-On-Off. See
Table 9-2.
See Section 3.3, “Hot-Plug Feature.”
Refer to
SunVTS User’s Guide.
See Figure 10-6.