Symbol Technologies DS6708 Scanner User Manual


 
13 - 24 DS6708 Digital Scanner Product Reference Guide
Code 39 Full ASCII Conversion
Parameter # 11h
Code 39 Full ASCII is a variant of Code 39 which pairs characters to encode the full ASCII character set. To
enable or disable Code 39 Full ASCII, scan the appropriate bar code below.
Code 39 Buffering - Scan & Store
Parameter # 71h
This feature allows the digital scanner to accumulate data from multiple Code 39 symbols.
Selecting the Scan and Store option (Buffer Code 39) temporarily buffers all Code 39 symbols having a leading
space as a first character for later transmission. The leading space is not buffered.
Decode of a valid Code 39 symbol with no leading space causes transmission in sequence of all buffered data
in a first-in first-out format, plus transmission of the “triggering” symbol. See the following pages for further
details.
When the Do Not Buffer Code 39 option is selected, all decoded Code 39 symbols are transmitted
immediately without being stored in the buffer.
Enable Code 39 Full ASCII
(01h)
*Disable Code 39 Full ASCII
(00h)
NOTE Trioptic Code 39 and Code 39 Full ASCII cannot be enabled simultaneously.
Code 39 Full ASCII to Full ASCII Correlation is host-dependent, and is therefore described in the
ASCII Character Set Table for the appropriate interface. See the ASCII Character Set for USB on
page 6-12 or the ASCII Character Set for RS-232 on page 7-19.