Symbol Technologies DS6708 Scanner User Manual


 
RS-232 Interface 7 - 3
RS-232 Parameter Defaults
Table 7-1 lists the defaults for RS-232 host parameters. To change any option, scan the appropriate bar
code(s) provided in the RS-232 Host Parameters section beginning on page 7-4.
NOTE See Appendix A, Standard Default Parameters for all user preferences, hosts, symbologies,
and miscellaneous default parameters.
Table 7-1
RS-232 Host Default Table
Parameter Default
Page
Number
RS-232 Host Parameters
RS-232 Host Types Standard 7-6
Baud Rate 9600 7-7
Parity Type None 7-9
Stop Bit Select 1 Stop Bit 7-10
Data Bits 8-Bit 7-10
Check Receive Errors Enable 7-11
Hardware Handshaking None 7-11
Software Handshaking None 7-13
Host Serial Response Time-out 2 Sec 7-15
RTS Line State Low RTS 7-16
Beep on <BEL> Disable 7-16
Intercharacter Delay 0 msec 7-17
Nixdorf Beep/LED Options Normal Operation 7-18
Ignore Unknown Characters Send Bar Code 7-18