11-15
Symbologies
UPC/EAN Supplemental Redundancy
With Autodiscriminate UPC/EAN Supplementals selected, this option adjusts the
number of times a symbol without supplementals is decoded before transmission. The
range is from two to thirty times. Five or above is recommended when decoding a mix of
UPC/EAN symbols with and without supplementals, and the autodiscriminate option is
selected. The default is set at 20.
Scan the bar code below to set a decode redundancy value. Next, scan two numeric bar
codes beginning on page D-1 in Appendix D. Single digit numbers must have a leading
zero. If you make an error, or wish to change your selection, scan Cancel on page D-5.
UPC/EAN Supplemental Redundancy