©2001 Innoveta
TM
Technologies, Inc. 1/2 10/19/2001
Revision 2
Product Brief: Veta™ iHA Series – Half Brick
©2001 Innoveta Technologies™, Inc.
iHA48060A018V product brief 090302.doc
9/4/2002
' (877) 498-0099
1
/
2
Base Product Code Input
Voltage
Output
Voltage
Output
Current
Efficiency
iHA48060A018V 36-75V 1.8V 60A 86.5%
Input Characteristics
Operating input range 36-75V
Transient input voltage 100V 100mS max
Turn-on voltage 34V
Turn-off voltage 32V
Start-up time 80 mS On/Off to 90% Vout
Maximum input current 3.7A Input 0-75V, Io,max
Output Characteristics
Output voltage tolerance +/- 3% max Over line, load, and temp
to end of life
Efficiency see product table Full load
Line regulation 2 mV Over rated input
Load regulation 6 mV Over rated load
Output voltage adjustment 54%-110% %Vout,nom
Output ripple 50 mVp-p 20MHz bandwidth
Dynamic response
Transient voltage
Recovery time
100 mV
350 uS
Load step 25% of Io,max
slew rate =0.1A/us
Ripple frequency 300 kHz Fixed
Protection
Current limit inception 120% of Io,rated
Short circuit Continuous protection Auto-recovery (AR) hiccup
Output over voltage 136% of Vout,nom Latch (AR-optional)
Thermal shutdown 120C Auto recovery hiccup
Environmental
Operating temperature -40C to 120C Measurement point in full
datasheet
Its
86.5% efficiency
and superior thermal performance make the Veta™
Family of power modules ideally suited for power-hungry applications in
demanding thermal environments. This rugged building block is
designed to serve as the core of your high reliability system. A wide
output voltage trim range, -46 to +10%, and remote sensing are
standard features enhancing versatility. For a full-featured version of the
Veta™ Half Brick, including active current sharing, see the iHD product
brief.
Typical Performance
Features
• Standard Half Brick footprint
• High efficiency, typical 86.5%
• Wide output trim voltage
• True 60A product at 1.8V output
• Industry-leading output power:
108W
• Monotonic start-up
• Starts with a pre-biased output
• Basic insulation – 1500 Vdc
• Auto-recovery protection:
o Input under and over voltage
o Current limit
o Short circuit
o Thermal limit
• Latched output over voltage
• Optional auto-recovery output over
voltage
• High reliability open frame, surface-
mount construction
• Baseplate for improved thermal
management
• Constant switching frequency
• Optional 0.110” pin length
• Safety agency approvals pending
• Multiple patents pending
Veta™ iHA Series DC/DC Power Modules
48V Input, 60A Output
Half Brick