3. GENERAL PRODUCT SPECIFICATIONS
Dimensions: 5.3 x 4.0 x 1.375 inches
Weight: 1 lb
Voltage Supply: : 8 to 24 VDC
7 to 16 VAC, 50/60 Hz
Optional Wall Transformer 115 VAC, 50/60 Hz
Current Requirements: (See Section 4 for Power Down Modes)
MIU PowerPort 2.4:
12VDC 24VDC 125VDC 120VAC 220VAC
65mA 27mA 7.5mA 6.5mA 5.5mA
MIU PowerPort 9.6:
12VDC 24VDC 125VDC 120VAC 220VAC
115mA 57mA 11mA 10mA 9mA
MIU1 PowerPort 4.4:
12VDC 24VDC 125VDC 120VAC 220VAC
160mA 69mA 14mA 12mA 9mA
MIU PowerPort 28.8:
12VDC 24VDC 125VDC 120VAC 220VAC
205mA 125mA 16mA 15mA 11mA
Surge Protection: Power Supply: 8kVrms
Analog Line: 5kVac (MIU2.4 & 9.6)
3.75kVac (MIU14.4 & 28.8)
Digital Line: ESD ± 10kV
Operating Temperature: -40 to +85 deg C
Operating Humidity: 0 to 90% (non-condensing.)
Storage Temperature: -55 to 100 deg C
* Note: At temperatures below 0° F, an additional current drain of up to 350 ma