Table 10.8-4 Identify Information (Continued)
WORD DESCRIPTION Hex.
87 Command set/feature default
15 0 (Fixed)
14 1 (Fixed)
13 1 (Fixed)
12-6 Reserved
5 1=General Purpose Logging feature set supported
4 Reserved
3 1=Media Card Pass Through Command feature set enabled
2 1=Madia serial number is valid
1 1=SMART self-test supported
6023
88 15-8 Ultra DMA transfer mode selected
7-0 Ultra DMA transfer modes supported
XX3F
89 Time required for security erase unit completion 00XX
90 Time required for Enhanced Security erase completion 0000
91 Current Advanced Power Management setting
15-8 Reserved
7-0 Current Advanced Power Management setting set by Set Features
Command
00XX
92 Master Password Revision Code XXXX
93 Hardware reset result. The conetnts of bits 12-0 of this word shall change only
during the execution of a hardware reset.
15 0 (Fixed)
14 1 (Fixed)
13 1=device detected CBLID- above V
IH
0=device detected CBLID- below V
IL
12-8 Device 1 hardware reset result. Device 0 shall clear these bits to
zero.
Device 1 shall set these bits as follows :
12 Reserved.
11 0=Device 1 did not assert PDIAG-.
1=Device 1 asserted PDIAG-.
10-9 These bits indicate how Device 1 determined the device
number:
00=Reserved.
01=a jumper was used.
10=the CSEL signal was used.
11=some other method was used or the method is
unknown.
8 1 (Fixed)
7-0 Device 0 hardware reset result. Device 1 shall clear these bit to
zero.
Device 0 shall set these bills as follows:
7 Reserved.
6 0=Device 0 does not respond when Device 1 is selected.
1=Device 0 responds when Device 1 is selected.
5 0=Device 0 did not detect the assertion of DASP-.
1=Device 0 detected the assertion of DASP-.
4 0=Device 0 did not detect the assertion of PDIAG-.
1=Device 0 detected the assertion of PDIAG-.
3 0=Device 0 failed diagnostics.
1=Device 0 passed diagnostics.
2-1 These bits indicate how Device 0 determined the device
number:
00=Reserved.
01=a jumper was used.
10=the CSEL signa was used.
11=some other method was used or the method is
unknown.
0 1 (Fixed)
XXXX
94 Current automatic acoustic management value
15-8 Vendor’s recommended acoustic management value
7-0 Current automatic acoustic management value
0000
95-99 Reserved 0000
100-103 Maximum user LBA for 48-bit Address feature set XXXX
104-126 Reserved 0000