Toshiba B-570 SERIES Printer User Manual


 
6-15
EM18-33010A
6. DIAG. TEST OPERATION
[FEED] key: Pressing the [FEED] key one time
is a -0.5 mm change, up to -50.0
mm. (See NOTE 2.)
[RESTART] key: Pressing the [RESTART] key one
time is a +0.5 mm change, up to
+50.0 mm.
(See NOTE 2.)
6.3 PARAMETER SETTING MODE
6.3.1 Feed Length Fine Adjustment
NOTES: 1. Holding the [FEED] key or [RESTART] key down for more than 0.5 seconds enables
a fast forward.
2. Max. fine adjustment
±
50.0 mm = Key fine adjustment value (
±
50.0 mm) + PC fine
adjust ment value (
±
50.0 mm)
When the value reaches the maximum, the value remains unchanged even if the
subsequent fine adjustment is performed.
3. A change feed value is stored in memory by pressing the [PAUSE] key.
<
1 DIAGNOSTIC V1.0A
>
<
2 PARAMETER SET
>
Power off
F
E D ADJUST +0.0mmE
Turn on the power while
holding down the [FEED]
key and [PAUSE] key.
Press the [FEED] key.
Press the [PAUSE] key.
Press the [FEED] or
[RESTART] key to adjust
the feed length.
(See NOTE 1.)
Press the [FEED] key
and [RESTART] key
at the same time.
Press the [PAUSE] key.
Continued on Section 6.3.2
Cut/strip position fine adjustment.