Toshiba E6581830 Laptop Docking Station User Manual


 
E658130
- 36 -
2. Network parameter setting of the master station
Network parameters are set as below.
Item Setting Conditions
Start I/O No. 0000
Data link alarm
station setting
Input clear Operation
settings
Setting at CPU
stop
Refresh
Type Master
Mode Remote net
Ver.1 mode
All connect count 2
Remote input (RX) X1000
Remote output (RY) Y1000
Remote register (RWr) W0
Item Setting Conditions
Remote register (RWw) W100
Special relay (SB) SB0
Special resister (SW) SW0
Retry count 3
Automatic reconnection
station count
1
CPU down select Stop
Scan mode settings Asynchronous
Station
information
Station
type
Remote device
station